10.

Gauging Instructions

Position Dk-Lok no-go gap gauge in the gap between the nut and body hex.

When the gauge does not enter the gap, the fitting is sufficiently tightened.

When the gauge enter the gap, additional tightening is required.

11.

Precaution

1.

The pressure must be set as per the tabulation adhered on the swaging unit.

Incorrect pressure setting lead to faulty swaging.

2.

Long tube length must be supported during the swaging process

3.

Dirt, chip and others may interfere with swaging process.

The swaging dies should be thoroughly cleaned after each use.

Table 1 Table 2

Fitting size

Swaging Pressure(Bar)

Fraction

Metric

Thickness

Fraction

Metric

Unit: mm stainless carbon stainless carbon

1/2”

12mm

2

80

80

3/4”

20mm

2

120

120

1”

25mm

2

150

150

1-1/4” 32mm

3

140

140

1-1/2” 38mm

3

200

200

2“

50mm

3

220

220

Fitting size

Turn

Fraction

Metric

1/2”

12mm

1/2

3/4”

20mm

1/2

1”

25mm

1/2

1-1/4” 32mm

5/8

1-1/2” 38mm

5/8

2“

50mm

3/4