Table of Contents Table of Contents
Previous Page  149 / 235 Next Page
Information
Show Menu
Previous Page 149 / 235 Next Page
Page Background www.dklok.com

Valves

DK-LokTubeFittingCerti cationListing

DK-LokValveCerti cationListing

QualitySystemApprovals

V73 Series In-line Filters

• 

In-line filters are applicable where space is limited and 

elements don’t have to be replaced often.

Compact in-line design with large filtration area

Maximum working pressure 3,000 psig @100°F(206 bar @38°C)

V76 Series Tee Filters

Filter Element replaceable with the valve in-line.

Safety union bonnet design for high pressure rating

Optional Bypass for sampling or purging of process fluid.

Maximum working pressure 6,000 psig @100 °F(413 bar @38°C)

Outlet

Body

Element

Gasket

Spring

Nut

Retainer Ring

Cap

teltuO

telnI

Inlet

Outlet

No.V736-7

March 2014

V73 Series In-Line Filters

V76 Series Tee Filters

Pressure Rating up to 3000 psig (206 bar), 6000 psig (413 bar)

Filters for System Purity

Features

V76 Series Tee Filter CNG Certifications

Materials of Construction

Filtration Definitions

Traps fine contamination to maintain system purity

Gas and liquid filtration

Standardmicron filtering ranges

Sintered Elements : 0.5, 2, 7, 15, 60 and 90micron

Strainer Elements : 40,140,230 and 440micron

Certificates

ECE R110

ANSI / AGA NGV 3.1-1995

CGA NGV 12.3-M95

ISO 15500

Certificate No

110R-000196

Class 0

-40°C to 120°C (-40°F to 250°F )

200 bar @ 120°C

2010-REPORT-032 (01)

CNG-Filter

-40°C to 121°C (-40°F to 250°F )

273 bar @ 121°C

2010-REPORT-031(00)

CNG-Filter

-40°C to 121°C (-40°F to 250°F )

273 bar @ 121°C

Classification

Temperature

Working Pressure

Component

V73 Series

V76 Series

Grade/ASTM Specification

Body

SS316 / A276 Brass / B16 SS316 / A276 Brass / B16

Nut

-

-

SS316 / A276 Brass / B16

Cap

-

-

SS316 / A276 Brass / B16

Retainer Ring

-

-

Stainless Steel

Element

SS316 (Sintered, Strainer)

Spring

SS302

Gasket

SS316 / A240 silver plated

Wetted components are listed in

blue

.

• Filter Element :

The componentwithin thefilterwhich trapsmedia contamination.

• Filtration Area :

The actual surface area of the filter element available to trap

contamination.

• Micron :

Aunit ofmeasure todescribe themeanpore diameter of the filter

element or the mean particle diameter of media contamination.

One micron = 0.001mm or 0.00004 inch

Replaceable SS316 sintered and starainer elements

SS316 and Brass body construction

Choice of reliable DK-Lok, NPT & ISO pipe end connections

Heat Code Traceability

Outlet

Body

Element

Gasket

Spring

Nut

Retainer Ring

Cap

teltuO

telnI

Inlet

Outlet

Outlet

Body

Element

Gasket

Spring

Nut

Retainer Ring

Cap

teltuO

telnI

Inlet

Outlet

V73 Series In-line Filters

V76 Series Tee Filters