Pneumatic

Accessories

G

DPL418

877.963.4966 •

dixonvalve.com

393

G

L18 EconOmist

®

Compact Lubricators

Wilkerson FRL's

Flow Guide

®

The elastomer disc-shaped device is located in the throat of all Wilkerson lubricators and

automatically maintains a constant ratio of oil flow to airflow regardless of changing rates of

airflow. This allows one lubricator to serve several pneumatic components operating together

or intermittently.

Type of oil to use:

For all Wilkerson lubricators, use any petroleum-base, non-detergent light weight oil (SAE

10/150SSU) which will readily break up into a mist, i.e., Mobil DTE light or comparable oil. Do

not use synthetic oil or any oils containing additives or solvents. See page 367 for air tool

lubricants.

with metal bowl

Features:

4 oz. bowl

manual drain

high flow capacity

can be filled under pressure

To adjust and set oil delivery rate the unit must be pressurized and air must be flowing

through the unit. Turn the sight dome, located on the top of the unit, counter clockwise to

initiate oil delivery. The rate of oil delivery depends on air flow rate. If flow increases or

decreases, the oil delivery rate will increase or decrease proportionally. Turning the sight

dome clockwise will stop all oil delivery.

maximum operating conditions:

- transparent bowl:

150 PSIG

(10.3 bar) and

32°F

to

125°F (0°C

to

52°C)

- metal bowl:

250 PSIG

(17.2 bar) and

32°F

to

150°F

(0°C

to

66°C)

Size Flow

(SCFM)

Transparent Bowl

Part #

Metal Bowl

Part #

¼"

88

L18-02A

L18-02AMB

⅜"

90

L18-03A

L18-03AMB

½"

96

L18-04A

L18-04AMB

L26 EconOmist

®

Standard Lubricators

with metal bowl

Features:

10 oz. bowl

adjustable oil feed

can be filled under pressure

quick-disconnect metal bowl guard with integral safety latch

siphon tube filter provides clean lubricant downstream

The rate of oil delivery may be controlled by turning the adjusting screw counter clockwise for

more and clockwise for less oil delivery. If flow increases or decreases, the oil delivery rate

will increase or decrease proportionally.

maximum operating conditions:

- transparent bowl:

150 PSIG

(10.3 bar) and

32°F

to

125°F

(0°C

to

52°C)

- metal bowl:

200 PSIG

(13.8 bar) and

32°F

to

150°F

(0°C

to

66°C)

1

metal bowl has sight gauge with brass petcock drain

Size Flow

(SCFM)

Transparent Bowl

Metal Bowl

1

Part #

Part #

¼"

35

L26-02A

L26-02AMB

⅜"

60

L26-03A

L26-03AMB

½" 128

L26-04A

L26-04AMB

SCFM ratings at 150 PSIG inlet pressure.