G
Wilkerson FRL's
R40 High Pressure High Flow Regulators
Features:
•
0-180 PSI adjusting range
•
self-relieving standard
•
piston operated
•
can be installed with the adjusting knob in any position
•
To increase regulated pressure, pull adjusting knob up and turn clockwise. To reduce
pressure, turn knob counter clockwise.
•
two ¼" NPT gauge ports standard on models without gauge, one ¼" NPT gauge port
standard on models with gauge - can be used for additional outlet ports
•
models supplied without gauge use a GC240 gauge
•
maximum operating conditions:
300 PSIG
(20.7 bar) and
32°F
to
150°F
(0°C
to
66°C)
Size Flow
(SCFM)
With Gauge
Part #
Without Gauge
Part #
1½" 1200
R40-0BRHG
R40-0BRH
2" 1200
R40-0CRHG
R40-0CRH
R40 High Flow Regulators
Features:
•
0-125 PSI adjusting range
•
self-relieving standard
•
piston operated
•
can be installed with the adjusting knob in any position
•
To increase regulated pressure, pull adjusting knob up and turn clockwise. To reduce
pressure, turn knob counter clockwise.
•
two ¼" NPT gauge ports standard on models without gauge, one ¼" NPT gauge port
standard on models with gauge - can be used for additional outlet ports
•
models supplied without gauge use a GC230 gauge
•
maximum operating conditions:
300 PSIG
(20.7 bar) and
32°F
to
150°F
(0°C
to
66°C)
Size Flow
(SCFM)
With Gauge
Part #
Without Gauge
Part #
1½" 1200
R40-0BRG
R40-0BR
2" 1200
R40-0CRG
R40-0CR
SCFM ratings at 100 PSIG inlet pressure.
See pages 401 to 405 for accessories.
FRL's are designed for air service only, unless otherwise indicated.