Simple Filter Troubleshooting

General Purpose Filter

Bowl

Baffle

Service indicator

(optional)

Body

Louvre

Centre post

Element

Metal bowl

sight glass

Collected

condensate

Drain

Malfunction

Possible cause

Remedy

Excessive pressure drop

Micron rating of element too

small.

Filter element blocked.

Flow requirement greater

than filter capacity.

Use larger micron element

size for application.

1. Clean element

(not coalescing element).

2. Replace with new element.

Use larger filter.

Dirt passing through filter

Element seals missing or

defective (N.B. Seals not

required on some units).

Damaged element.

1. Replace seal.

2. Tighten element.

Replace element.

Water passing through filter

Water level in bowl above

baffle.

Flow capacity of filter

exceeded.

Drain water.

Maintain flow within capacity

of filter or change to filter

capable of handling desired

flows.

Crazing of polycarbonate

bowl or milky appearance

Bowl has been cleaned with

incompatible fluid.

Bowl is being used in an area

containing fumes or

vapors in-compatible with

polycarbonate.

Compressor oil vapor may be

causing problem.

Air intake to compressor may

contain fumes or vapor

in-compatible with

polycarbonate.

Replace bowl.

(Clean only with clean warm

water and soap.)

Replace bowl.

Eliminate source of problem

or

convert from plastic to metal

bowls.

Replace bowl.

Eliminate source of problem

or

convert from plastic to metal

bowls.

Replace bowl.

Eliminate source of problem

or

convert from plastic to metal

bowls.

Water beyond the filter

Inlet air has a high

temperature and as it cools

downstream, moisture

condenses to water.

Fit dryer, pre-cool air or fit

filter immediately prior to

application.