DPL116

877.963.4966 •

dixonvalve.com

W

848

Malfunction

Possible cause

Remedy

No Drip Rate

Oil adjustment knob fully

clockwise

Low oil level

Airflow through lubricator too

low

Blocked oil filter screen

Air leaks

Readjust knob.

Check oil level.

Use smaller size lubricator.

Remove bowl and sight feed

adjustment dome and clear

syphon tube.

Remove sight feed adjustment

dome and clean or replace

screen located in dome

assembly.

Check bowl, filler plug and

sight dome seals. Tighten if

necessary.

Oil Foaming

Over aeration

Check bowl seals for slight

leaks.

Oil Emulsified

Water in lubricator

Fit filter immediately upstream.

Drip Rate changes after setting Fade

Readjust drip rate.

Simple Lubricator Troubleshooting

Oil-Fog Lubricator

Metal

bowl

sight

glass

Sight

dome

Body

Flow

sensor

Check

valve

Bowl

Syphon

tube

Oil

Drain

(optional)

Setting Lubricator Drip Rates

What is the correct drip rate setting?

The drip rate will depend on the application, the amount of lubrication required, the flow through the lubricator and the

lubricator type. In micro-fog lubricators only 10% of the droplets in the sight dome are carried downstream. The drip rate

in micro-fog lubricators therefore tends to be much higher. The following table can be used to estimate drip rate for required flow.

This is very much a rule of thumb. In practice it is necessary to fine tune the oil drip rate in each application.

Can the drip rate be shut off?

In lubricators with needle valve type sight dome, yes.

Some sight domes use a felt pad which is soaked in oil at the point where the drops are formed. With this type of sight dome the

oil droplets cease once the felt pad dries out. With the new style dome (L72/73/74 and L07) complete shut

off is not possible. Minimum adjustment for the drip rate is around 1 drop per minute.

Typical Drip Rate per Minute

Micro-Fog

Typical Drip Rate per

Oil-Fog

Approximate Flow

SCFM (dm

3

/s)

20

2

10 (5)

40

4

20 (10)

60

6

30 (15)

80

8

40 (20)

100

10

50 (25)

120

12

60 (30)