Table of Contents Table of Contents
Previous Page  844 / 932 Next Page
Information
Show Menu
Previous Page 844 / 932 Next Page
Page Background

Technical Information

DPL116

877.963.4966 •

dixonvalve.com

W

842

Feet Head of Water to PSI

One foot of water at 62°F = 0.433 PSI, to find the PSI for any feet head not given in the table, multiply the feet head by 0.433.

Air Supply Requirements

(operating pressure - 90 PSI)

Tool

Class

Typical Air Consumption (CFM)

Hose Size (inches)

0-10 ft.

10-50 ft.

50-200 ft.

Paving Breakers

25 lb.

35 lb.

60 lb.

80 lb.

45

50

65

80

1/2

1/2

1/2

3/4

1/2

3/4

3/4

3/4

3/4

3/4

1

1

Claydiggers

45

1/2

1/2

3/4

Hand Drills

8 lb.

15 lb.

20

32

3/8

3/8

3/8

1/2

1/2

1/2

Rock (Sinker) Drills

45 lb.

55 lb.

105

130

3/4

3/4

3/4

1

1

1

Tampers

5" butt

6" butt

20

30

3/8

1/2

1/2

1/2

1/2

3/4

Sump Pump

Sludge Pump

3 HP

Ejector

100

90

3/4

1

3/4

1

1

1

Vibrators

2½"

3"

60

60

1

1

1

1

1

1

Chipping Hammers

25

3/8

1/2

1/2

Impact Wrenches

⅜" sq. dr.

1/2"

3/4"

1"

10

15

25

50

5/16

5/16

3/8

1/2

3/8

3/8

1/2

3/4

3/8

1/2

1/2

3/4

Drills

¼" - ½"

22

3/8

3/8

1/2

Grinders

die/burr

small angle

3 HP vertical

20

20

75

3/8

3/8

1/2

3/8

3/8

3/4

1/2

1/2

1

Feet Head Pounds per

Square Inch

1

0.43

2

0.87

3

1.30

4

1.73

5

2.17

6

2.60

7

3.03

8

3.46

9

3.90

10

4.33

Feet Head Pounds per

Square Inch

15

6.50

20

8.66

25

10.83

30

12.99

40

17.32

50

21.65

60

25.99

70

30.32

80

34.65

90

38.98

Feet Head Pounds per

Square Inch

100

43.31

110

47.64

120

51.97

130

56.30

140

60.63

150

64.96

160

69.29

170

73.63

180

77.96

200

86.62

Feet Head Pounds per

Square Inch

250

108.27

300

129.93

350

151.58

400

173.24

500

216.55

600

259.85

700

303.16

800

346.47

900

389.78

1000

433.00

Applied

Pressure

PSI

Nominal Standard Pipe Size

⅛"

¼"

⅜"

½"

¾"

1"

1¼"

1½"

2"

2½"

3"

5

0.5

1.2

2.7

4.9

6.6

13

27

40

80

135

240

10

0.8

1.7

3.9

7.7

11.0

21

44

64

125

200

370

20

1.3

3.0

6.6 13.0 18.5

35

75

110

215

350

600

40

2.5

5.5 12.0 23.0 34.0

62

135

200

385

640 1100

60

3.5

8.0 18.0 34.0 50.0

93

195

290

560

900 1600

80

4.7 10.5 23.0 44.0 65.0

120

255

380

720 1200 2100

100

5.8 13.0 29.0 54.0 80.0

150

315

470

900 1450 2600

150

8.6 20.0 41.0 80.0 115.0

220

460

680 1350 2200 3900

200

11.5 26.0 58.0 108.0 155.0

290

620

910 1750 2800 5000

250

14.5 33.0 73.0 135.0 200.0

370

770 1150 2200 3500 6100

Maximum Recommended Air Flow (SCFM)

Through ANSI Standard Weight Schedule 40 Metal Pipe

Flow values in the table below are based on a pressure drop of 10% of the applied pressure per 100 feet of pipe for ⅛", ¼",

⅜", and ½" pipe sizes; and a pressure drop of 5% of the applied pressure per 100 feet of pipe for ¾", 1", 1¼", 2", 2½", 3" pipe

sizes. The table gives recommended flows for pipe sizes at listed pressures and should be used to determine appropriate

piping for air systems.