Instructions for Use
WT 7984 E 10.12
Conveyor Belt Group
ContiTech Transportbandsysteme GmbH
D-37154 Northeim
Tel. +49 5551 702-1643
transportbandsysteme@cbg.contitech.deone
step – one solution
Conti Secur
®
PREMIUM
Conti Secur
®
PREMIUM
The one-component adhesive based on polychloroprene.
The content of this publication is not legally binding and is provided as information only. The trademarks
displayed in this publication are the property of Continental AG and/or its affiliates. Copyright © 2012 ContiTech AG.
All rights reserved. For complete information go to:
www.contitech.de/discl_en www.contitech.de/cbg-csp-eRubber-to-metal adhesion
-Contact layer material-
1. Preparation of the cold bonding
1.1 Clean the surface of the metal and the contact layer using cleansing agent (CCS).
Caution:
If the rubber coating with the contact layer material has been stored
for a longer period of time, we recommend roughening the surface of the contact
layer material with a grinding disk (grade 40 or 60).
1.2 Roughen the metal surface by sand-blasting or with the aid of an angle grinder.
Grit of the grinding disk: 16 or 24. Remove the grinding dust dry.
2. Bonding
2.1 Thoroughly stir the adhesive agent CONTI PLUS
®
prior to processing,
and apply one thin coat to the metal surface.
Drying time:
At least 30 minutes at room temperature
Caution:
Coated parts can be stored up to a maximum
of 2 weeks at room temperature.
2.2 Apply one coat of Conti Secur
®
PREMIUM to the metal surface.
Drying time:
At least 30 minutes at room temperature
Caution:
Do not use a brush with short bristles, as otherwise
the CONTI PLUS
®
coating could come off again.
2.3 Cut the rubber coating to size.
Second application of Conti Secur
®
PREMIUM on the metal surface.
2.4 One coating of Conti Secur
®
PREMIUM onto the surface of the contact layer.
Drying time:
Maximum of 10 minutes (test with back of hand).
2.5 Put the coated surfaces together. Press on the surfaces from the
inside outwards, e.g. using a hand-held roller or a dead-blow hammer.
Caution:
Brief contact pressure is sufficient.
Optimum adhesion strength is attained after approx. 24 hours.