Table of Contents Table of Contents
Previous Page  643 / 961 Next Page
Information
Show Menu
Previous Page 643 / 961 Next Page
Page Background

Sanitary

Fittings

J

646

DPL418

877.963.4966 •

dixonvalve.com

J

Actuation: Pneumatically Actuated

Pneumatically Actuated Stainless Steel Ball Valves

Features:

3-Piece Stainless Steel Ball Valve

body, ends and ball

:

CF8M stainless

seats: RTFE

seals: PTFE

blow-out proof stem

live-loaded stem packing

ISO 5211 mounting pad

pressure rating: ¼" - 2"

1000 PSI

WOG, 2½" - 3"

800 PSI

WOG

temperature range: ¼" to 2"

: -40°F

to

350°F (-40°C

to

177°C),

2½" to 3":

-40°F

to

325°F

(-40°C

to

163°C)

Rack and Pinion Actuator

body: hard anodized aluminum

anti-blowout pinion: nickel plated anti-blowout pinion

O-rings: Buna-N

NAMUR mounting

bi-directional stops for ±5º travel adjustment

• 80 PSI

plant air required

visual position indication

maximum operating pressure:

120 PSI

temperature range:

-40ºF

to

200ºF (-40°C

to

93°C)

tested to one million cycles

for spring return actuators must note fail position

A wide variety of options are available: spring return (normally closed) and double acting actuators, switches, solenoids,

positioners, etc. Contact Dixon Sanitary at 800.789.1718.

3-Piece

Features:

3-Piece Stainless Steel Ball Valve

body and ball: CF8M stainless steel

stem: 316 stainless steel

seat: RTFE

blow-out proof stem

live-loaded stem packing

ISO 5211 mounting pad

swing out design allows easy maintenance

maximum pressure: ¼" - 2"

1,000 PSI

WOG at 65°F,

2½" - 3"

800 PSI

WOG at 65°F, 4"

600 PSI

WOG at 65°F

temperature range: ½" to 2"

-40°F

to

350°F (-40°C

to

177°C) ,

3" to 4":

-40°F

to

325°F

(-40°C

to

163°C)

Rack and Pinion Actuator

body: hard anodized aluminum

anti-blowout pinion: nickel plated

O-rings: Buna-N

NAMUR mounting

bi-directional stops for ±5º travel adjustment

80 PSI plant air required

visual position indication

maximum operating pressure:

120 PSI

temperature range:

-40ºF

to

200ºF (-40°C

to

93°C)

tested to one million cycles

for spring return actuators must note fail position

2-Piece

Even though there are torque safety factors built into our automated ball valve packages, actual service conditions

must also be considered when selecting the proper product for the appropriate application.

For example: Severe service conditions such as dirty water, dirty air, all slurries, raw sewage water, oils, and other

viscous fluids can have a dramatic affect in raising the torque requirements of ball valves as much as 75% and

therefore larger actuators may be required. Please consult Dixon

®

when dealing with these types of applications.