G-79
Pneumatic Fittings
DPL417
877.963.4966 •
dixonvalve.comG
FRL's
Wilkerson EconOmist
®
Standard Lubricators L40 & L50
illustration represents L40 series
transparent bowl with guard
Features:
•
26 oz. bowl
•
transparent bowl: solid bottom
metal bowl: manual drain with sight glass
•
full view sight dome
•
adjustable oil feed
•
can be filled under pressure
•
quick-disconnect clamp ring for easy bowl removal
•
The rate of oil delivery may be controlled by turning the adjusting screw counter clockwise
for more and clockwise for less oil delivery. The oil delivery rate will change automatically to
deliver more oil during higher air flows and less oil for air flows lower than the one at which
the setting was made.
•
maximum operating conditions:
- transparent bowl:
150 PSIG
(10.3 bar) and
32°F
to
125°F
(0°C
to
52°C)
- metal bowl:
200 PSIG
(13.8 bar) and
32°F
to
150°F
(0°C
to
66°C)
Size Flow
(SCFM)
With Transparent Bowl
With Metal Bowl with Sight Glass
Part #
Price/E
Part #
Price/E
1½" 927
L40-0BA
$681.15
L40-0BAMB
$740.70
2" 1186
L50-0CA
924.00
L50-0CAMB
983.20
Wilkerson Compact Combination Units C16
transparent bowl with guard
Filter series F16:
•
5 micron element
•
5 oz. bowl
Regulator series R16:
•
0-125 PSI adjusting range
•
self-relieving
•
supplied with a GC230 gauge
Lubricator series L16:
•
5 oz. bowl
•
adjustable oil feed
•
full view sight dome
Features:
•
maximum operating conditions:
- transparent bowl:
150 PSIG
(10.3 bar) and
32°F
to
125°F (0°C
to
52°C)
- metal bowl:
200 PSIG
(13.8 bar) and
32°F
to
175°F
(0°C
to
80°C)
•
Included components:
- (2) modular sleeves
- (2) mounting brackets (sleeve and bracket)
- (2) end blocks
Size Flow
(SCFM)
With Transparent Bowl and Guard With Metal Bowl with Sight Glass
Automatic Drain Manual Drain
Automatic Drain
Manual Drain
Part # Price/E Part # Price/E Part # Price/E Part # Price/E
¼" 36.1
C16-02A
$653.05
C16-02M
$593.00
C16-02AMB
$689.15
C16-02MMB
$629.10
⅜" 58.5
C16-03A
653.05
C16-03M
593.00
C16-03AMB
689.15
C16-03MMB
629.10
½" 64.0
C16-04A
653.05
C16-04M
593.00
C16-04AMB
689.15
C16-04MMB
629.10
SCFM ratings at 150 PSIG inlet pressure.
FRL's are designed for air service only, unless otherwise indicated.
SCFM ratings at 120 PSIG inlet pressure.
See pages G-85 to G-89 for accessories.
See page G-51 for air tool lubricant.
FRL's are designed for air service only, unless otherwise indicated.