Table of Contents Table of Contents
Previous Page  124 / 235 Next Page
Information
Show Menu
Previous Page 124 / 235 Next Page
Page Background

V16 Series

Union Bonnet Valves

Operation Information

mation

Curve 1

Actuator Ordering Information

Curve 1

Double Acting Dimensions

Double Acting Actuator Technical Data

Pneumatic Actuator Applicability

Curve 1 and 2 indicate the minimum actuator pressure to open or close double acting actuator against system pressure.

To prolong valve life, actuators should be operated at minimum air actuator pressures.

Curves shown are based on packing bolt factory adjustment.

Packing bolt adjustment may be required to maintain the valve leak-tight.

If the packing bolt is over-tightened, the actuating pressure can not overcome the friction force between the over-tightened packing

and the stem. If the packing bolt is under-tightened for low system pressures, it may leak at high system pressures.

However, packing bolt torque must be sufficiently maintained to prevent packing from leakage.

V16A series with Double Acting Actuator -AD

To order valves with a pneumatic double acting actuator, insert the desired

actuator designator from the chart in the valve ordering number.

Example: V16B-D6T-PK-B-

BD

-S

Valve Series

Double Acting Designator

V16A

AD

V16B

BD

V16B series with Double Acting Actuator - BD

Valve

Series

Dimensions in. (mm)

A

H

D

C

B

V16A

4.22 (107)

5.91 (150)

3.25 (82.6)

3.25 (82.6)

1.12 (28.4)

V16B

4.47 (114)

6.22 (158)

4.25 (108)

3.81 (96.8)

1.19 (30.2)

All dimensions are reference only and subject to change.

Maximum applicable pressure

Temperature ratings °F ( °C)

150 psig (10.4 bar)

-20 to 300 (-28 to 204)

V16A and V16B series valves with PTFE or PEEK packing are applicable to pneumatic

actuator. Those valves with Grafoil packing are not applicable to pneumatic actuator.

0

2

4

6

8

10

50

50

100

150

100 150 200 250 300 350 400

1,000 2,000 3,000 4,000 5,000 6,000

Minimum Actuator Pressure, bar

Minimum Actuator Pressure, psig

System Pressure, psig

System Pressure, bar

V16A Series

with PTFE Packing

V16A Series

with PEEK Packing

0

2

4

6

8

10

50

50

100

150

100 150 200 250 300 350 400

1,000 2,000 3,000 4,000 5,000 6,000

Minimum Actuator Pressure, bar

Minimum Actuator Pressure, psig

System Pressure, psig

System Pressure, bar

V16B Series

with PTFE Packing

V16B Series

with PEEK Packing

0

2

4

6

8

10

50

50

100

150

100 150 200 250 300 350 400

1,000 2,000 3,000 4,000 5,000 6,000

Minimum Actuator Pressure, bar

Minimum Actuator Pressure, psig

System Pressure, psig

System Pressure, bar

V16A Series

with PTFE Packing

V16A Series

with PEEK Packing

0

2

4

6

8

10

50

50

100

150

100 150 200 250 300 350 400

1,000 2,000 3,000 4,000 5,000 6,000

Minimum Actuator Pressure, bar

Minimum Actuator Pressure, psig

System Pressure, psig

System Pressure, bar

V16B Series

with PTFE Packing

V16B Series

with PEEK Packing

0

2

4

6

8

10

50

50

100

150

100 150 200 250 300 350 400

1,00 2,00 3,00 4,00 5,00 6,00

Minimum Actuator Pressure, bar

Minimum Actuator Pressure, psig

System Pressure, psig

System Pressure, bar

V16A Series

with PTFE Packing

V16A Series

with PEEK Packing

0

2

4

6

8

10

50

50

100

150

100 150 200 250 300 350 400

1,00 2,00 3,00 4,00 5,00 6,00

Minimum Actuator Pressure, bar

Minimum Actuator Pressure, psig

System Pressure, psig

System Pressure, bar

V16B Series

with PTFE Packing

V16B Series

with PEEK Packing

Safe Valve Selection

The selection of a valve for any application or systemdesignmust be considered to ensure safe performance.

Valve function, valve rating,material compatibility, proper installation, operationandmaintenance remain the sole responsibility of the system

designer and the user. DK-Lok accepts no liability for any improper selection, installation, operation or maintenance.

V16 series Pneumatic actuators are designed to actuate valves remotely. V16A and V16B series are available to be equipped with

pneumatic actuators in double acting.

Double Acting Pneumatic Actuator