3
A
-PK
GF
-B
-AH
-SG
-BD
-S
Valve Pattern
Designator
Packing Material
Designator
Stem Disc
Designator
Handle
Designator
Sour Gas
Designator
Pneumatic Double
Acting Actuator
Valve Material
Designator
Nil
: In-line
A
: Angle
Nil
: PTFE
PK
: PEEK
GF
: Grafoil*
Nil
: Globe
R
: Regulating
B
: Ball
Nil
: SS316 bar handle
AH
: Aluminum Bar handle
Nil
: no Sour Gas
SG
: Sour Gas
AD
: V16A series valves
BD
: V16B series
valves
S
: SS316
M
: Alloy 400
HC
: Alloy C276
We reserve the right to change the specifications stated in this catalog for our continuing program of improvement.
V16 Series
Union Bonnet Valves
Pressure-Temperature Ratings
Flow Data @ 100°F (38°C) for valves with regulating disc
Ordering Information
Valve ratings with optional PEEK packing
SS316 and C276 valvewith PEEK packing is limited tomaximum600 °F (315 °C) rating ; Alloy 400
valve with PEEK packing is limited to maximum 500 °F (260 °C) rating.
Select the desired valve basic ordering number, options and body material.
Grafoil packing information
Globe and Ball Disc
Sour Gas Valves
Optional Handles
Valve ratings with DK-Lok end connections
Cv reduction
Packing adjustment and actuation torque
Ratings are based on valves with optional Grafoil packing.
ASME Class
2500
N/A
Material Group
2.2
3.4
N/A
Material Name
SS316
Alloy 400 Alloy C-276
Temperature, °F (°C)
Working pressure, psig (bar)
–65 (–53) to 100 (38)
6000 (413)
5000 (344)
6000 (413)
200 (93)
5160 (355)
4400 (303)
6000 (413)
300 (148)
4660 (321)
4120 (283)
6000 (413)
400 (204)
4280 (294)
3980 (274)
5880 (405)
500 (260)
3980 (274)
3960 (272)
5540 (381)
600 (315)
3760 (259)
-
5040 (347)
700 (371)
3600 (248)
-
4730 (325)
800 (426)
3460 (238)
-
4230 (291)
900 (482)
3280 (225)
-
3745 (258)
1000 (537)
3030 (208)
-
3030 (208)
1100 (593)
2685 (184)
-
2685 (184)
1200 (648)
1715 (118)
-
1545 (106)
Grafoil is a high temperature packing material that requires a load on
the material to generate a seal.
In air, Grafoil maximum temperature is 973°F (523°C), in steam, Grafoil
goes up to themaximum temperature of 1,200°F (648° C). Grafoil packing
is not for use with pneumatic actuating valves.
Valve with standard globe and ball disc is designed for use in a fully open
or fully closed position.
Refer to Cv in the ordering information and dimensions table on Page 2.
Valves for use in sour gas are available. Valve wetted components are selected to the requirements of NACE MR0175 for
sulfide stress cracking resistant materials. To order, insert -SG in the basic ordering number.
SS316 bar handle is standard. Optional anodized black
aluminumbar handle is available.
To order valve with factory-assembled optional aluminum
handle, insert designator -AH in the ordering number.
To order handle for field assembly, select desired handle
ordering number from the table.
Valve
Series
Field Assembly Bar Handle
SS316
Aluminum
V16A
V16A-BH
V16A-AH
V16B
V16B-BH
V16B-AH
V16C
V16C-BH
V16C-AH
Valve ratings may be limited to the maximum working pressure of
connective pipe and tubing. For valve rating with DK-Lok tube fitting
end connections, refer to DK-Lok catalog providing suggested working
pressures in various tubing OD, wall thicknesses, and materials.
Valve flow may be reduced by the restriction of pipe and tubing
connected.
Extreme temperature fluctuations while valve in service may require
packing adjustment. Valves that have not been actuated for a period of
time may have a higher initial actuation torque.
8
6
4
2
0
0.8 1.0 1.2 1.4 1.6 1.8
0.2
0.4 0.6
NUMBER OF TURNS OPEN
FLOW COEFFICIENT (Cv)
V16A series
V16B series
V16C series
V16B-D-6T-
V16C-MF-12N-
*
Grafoil TM UCAR