Background Image
Previous Page  50 / 75 Next Page
Information
Show Menu
Previous Page 50 / 75 Next Page
Page Background

49

2015 Heavyweight Conveyor Belts

Flexsteel®

Recommended Minimum Pulley Diameters

Percent of Rated Tension

Belt Tension Rating

>100% - 125% 75 - 100%

50 - 75%

<50%

Snubs

Imperial (PIW)

600 - 1000

36

30

24

16

16

1001 - 1926

42

36

30

20

18

1927 - 2251

48

42

30

24

24

2252 - 2825

54

48

36

30

30

2826 - 3200

60

54

42

36

36

3201 - 3500

72

60

54

42

42

3501 - 4200

78

72

54

42

42

4201 - 4650

84

72

54

48

48

4651 - 6420

90

78

66

54

54

6421 - 6800

96

84

66

54

54

6801 - 8561

120

102

78

60

60

Metric (kN/m)

ST701-ST1169

1000

800

630

400

400

ST1170-ST2250

1000

1000

630

500

500

ST2251-ST2629

1250

1000

800

630

500

ST2630-ST3300

1250

1250

1000

800

630

ST3301-ST3738

1600

1400

1000

800

800

ST3739-ST4088

1800

1600

1250

1000

1000

ST4089-ST4906

2000

1800

1400

1000

1000

ST4907-ST5432

2000

1800

1400

1250

1250

ST5433-ST7499

2400

2000

1600

1250

1250

ST7500-ST7943

2400

2200

1600

1400

1400

ST7944-ST10000

3000

2500

2000

1400

1400

Snubs are defined as having 6 in. (152.4mm) or less belt contact and tension less than 50% of belt rating. Pulley sizes for Flexsteel® belts are determined by face pressure on the pulley

and/or the pulley-to-cable diameter ratio. All pulleys must be flat as crowned pulleys will cause excessive center tension in the high modulus steel cable product.

Flexsteel

®

Belts

Recommended Minimum Transition Distance at Half & Full Trough Depth

Minimum Transition Distance ( W = Belt Width ) by Idler Angle

Half Trough

Full Trough

Percent of Rated Tension

20 Deg

35 Deg

45 Deg

20 Deg

35 Deg

45 Deg

More than 90%

2.0W

3.4W

4.0W

4.0W

6.8W

8.0W

60% to 90%

1.6W

2.6W

3.2W

3.2W

5.2W

6.4W

Less than 60%

1.0W

1.8W

2.2W

2.0W

3.6W

4.4W

Snubs are defined as having 6 in. (152.4mm) or less belt contact and tension less than 50% of belt rating. Pulley sizes for Flexsteel® belts are determined by face pressure on the pulley

and/or the pulley-to-cable diameter ratio. All pulleys must be flat as crowned pulleys will cause excessive center tension in the high modulus steel cable product.