Plylon Plus® Troughability – Minimum Belt Width

Table based on ISO 703 Testing Procedure

Idlers

220/2 250/2 330/3 375/3 400/2 440/4 500/4 600/3 750/3 800/4 900/2 1000/4 1000/5 1200/6 1250/5 1350/3 1800/4

Inches

20 degree

18 18 18 20 18 24 24 24 24 30 24 30 36 42 36 30 36

35 degree

18 18 24 24 24 30 30 30 30 36 30 36 42 48 42 36 42

45 degree

24 24 30 30 30 36 36 36 36 42 36 42 48 54 48 42 48

Millimeters

20 degree

460 460 460 510 460 610 610 610 610 760 610 760 910 1070 910 760 910

35 degree 460 460 610 610 610 760 760 760 760 910 760 910 1070 1220 1070 910 1070

45 degree 610 610 760 760 760 910 910 910 910 1070 910 1070 1220 1370 1220 1070 1220

If top cover and pulley cover are balanced (i.e., 3/16 in.x3/16 in. or 5mm x 5mm) or less than 1/16 in. (2mm) differential (i.e., 3/16 in.x5/32 in. or 4mm x 3mm), add 6 in. (150mm) to the

minimum belt width. 6 in. (150mm) narrower widths are possible if the belt is broken in for an extended period of time fully loaded. Consult your Sales Representative. Additional break-in

time is required when the belt has been stored prior to insulation in ambient temperatures of less than 50°F (10°C).

Above tables are based on top cover gauge equal or greater than the bottom (pulley) cover gauge.

Plylon Plus® Minimum Pulley Diameters

Plylon

Plus

220/2

Plylon

Plus

250/2

Plylon

Plus

330/3

Plylon

Plus

375/3

Plylon

Plus

400/2

Plylon

Plus

440/4

Plylon

Plus

500/4

Plylon

Plus

600/3

Plylon

Plus

750/3

Plylon

Plus

800/4

Plylon

Plus

900/2

# of Plies

2

2

3

3

2

4

4

3

3

4

2

Inches

Over 80%

Tension

16

16

18

18

16

24

24

24

30

30

30

60% to 80%

Tension

14

14

16

16

14

20

20

20

24

24

24

40% to 60%

Tension

10

12

14

14

12

16

18

18

20

20

24

Up to 40%

Tension

10

12

14

14

10

16

18

16

18

18

20

Tails and Snubs 10

12

14

14

10

16

18

16

18

18

20

Millimeters

Over 80%

Tension

410

410

460

460

410

610

610

610

760

760

760

60% to 80%

Tension

360

360

410

410

360

510

510

510

610

610

610

40% to 60%

Tension

250

300

300

360

300

410

460

460

510

510

610

Up to 40%

Tension

250

300

300

360

250

410

460

410

460

460

510

Tails and Snubs 250

300

300

360

250

410

460

410

460

460

510

Plylon Plus® HT belts (2/900, 3/1350, 4/1800) require a minimum pulley cover gauge of 1/8 in. (3.18mm) if vulcanized splicing will be used.

Plylon Plus® 1000/4-1800/4 continued on page 18

2015 Heavyweight Conveyor Belts

Plylon Plus®

17