Page Background

Engineered Fluid

Transfer Couplings

A

61

DPL418

877.963.4966 •

dixonvalve.com

A

ADS Outalarms

ADS Outalarms with A100 Probe

Application:

specifically designed for liquid terminal operation on batch loading and overfill protection,

unloading, tank cars, tanks trucks, marine barges, suitable for open and closed dome

Features:

totally self-contained; no wires, tubing or external power

rugged weather and corrosion resistant construction

no moving parts, tip sensitive phase shift™ digital capacitance sensor for conductive and

non-conductive fluid

intrinsically safe design per ANSI/UL913 for Class I, Div I Groups A, B, C and D Hazardous

Areas

requires no calibration or adjustment

operates up to 2500 hours on a single 9V alkaline battery

adjustable insertion length through a standard ½" NPT fitting

high intensity audible and flashing visual outputs

full, hard graduated laser engraved rod

fail safe continuous battery monitor goes to alarm state on low battery

factory tuned to trip ¼" into liquid

24", 36", 48" and 60" probe lengths standard, other lengths available

battery current drain <0.23 ma during standby; <50 ma in alarm state

horn intensity 101 dB at 2'

light output 3 each 3000 mcd high intensity flashing LED's

wetted materials: 316 stainless steel, PTFE standard, other materials available

pressure rating on standard unit:

50 PSI

, consult Dixon

®

for applications up to 300 PSI

optional opto-isolated solid state contact output

high temperature applications to

325°F (162°C)

low temperature option good to

-40°F (-40°C)

temperature range:

-14°F

to

325°F (-26°C

to

163°C)

ADS Outalarms with Probe

Automated Design Service, Inc. (ADS) is now operating as Dixon

®

Industrial Fluid Control to manufacture products specifically

designed for liquid terminal operations. Our standard product offering is shown on the following pages. However, there are

numerous additional applications, materials and custom designs available, please visit

dixonvalve.com/ADS

for the latest

information. Call 513.874.8499 or 877.582.3569 for technical information or assistance with ordering these products.

ADS Outalarms

Features:

capacitance Phase Shift probe

½" NPT gland standard

minimum dielectric constant 1.8

temperature range: -

14°F

to

250°F (-26°C

to

121°C)

Length

Capacitance

250°F (121°C)

maximum

Hi-temp Capacitance

325°F (163°C)

maximum

Conductivity

for conductive fluids

12"

A100C12A

A100HC12A

A100CSS12A

24"

A100C24A

A100HC24A

A100CSS24A

36"

A100C36A

A100HC36A

A100CSS36A

48"

A100C48A

A100HC48A

A100CSS48A

60"

A100C60A

A100HC60A

A100CSS60A

72"

A100C72A

A100HC72A

A100CSS72A

84"

A100C84A

A100HC84A

A100CSS84A