Engineered Fluid
Transfer Couplings
A
61
DPL418
877.963.4966 •
dixonvalve.comA
ADS Outalarms
ADS Outalarms with A100 Probe
Application:
•
specifically designed for liquid terminal operation on batch loading and overfill protection,
unloading, tank cars, tanks trucks, marine barges, suitable for open and closed dome
Features:
•
totally self-contained; no wires, tubing or external power
•
rugged weather and corrosion resistant construction
•
no moving parts, tip sensitive phase shift™ digital capacitance sensor for conductive and
non-conductive fluid
•
intrinsically safe design per ANSI/UL913 for Class I, Div I Groups A, B, C and D Hazardous
Areas
•
requires no calibration or adjustment
•
operates up to 2500 hours on a single 9V alkaline battery
•
adjustable insertion length through a standard ½" NPT fitting
•
high intensity audible and flashing visual outputs
•
full, hard graduated laser engraved rod
•
fail safe continuous battery monitor goes to alarm state on low battery
•
factory tuned to trip ¼" into liquid
•
24", 36", 48" and 60" probe lengths standard, other lengths available
•
battery current drain <0.23 ma during standby; <50 ma in alarm state
•
horn intensity 101 dB at 2'
•
light output 3 each 3000 mcd high intensity flashing LED's
•
wetted materials: 316 stainless steel, PTFE standard, other materials available
•
pressure rating on standard unit:
50 PSI
, consult Dixon
®
for applications up to 300 PSI
•
optional opto-isolated solid state contact output
•
high temperature applications to
325°F (162°C)
•
low temperature option good to
-40°F (-40°C)
•
temperature range:
-14°F
to
325°F (-26°C
to
163°C)
ADS Outalarms with Probe
Automated Design Service, Inc. (ADS) is now operating as Dixon
®
Industrial Fluid Control to manufacture products specifically
designed for liquid terminal operations. Our standard product offering is shown on the following pages. However, there are
numerous additional applications, materials and custom designs available, please visit
dixonvalve.com/ADSfor the latest
information. Call 513.874.8499 or 877.582.3569 for technical information or assistance with ordering these products.
ADS Outalarms
Features:
•
capacitance Phase Shift probe
•
½" NPT gland standard
•
minimum dielectric constant 1.8
•
temperature range: -
14°F
to
250°F (-26°C
to
121°C)
Length
Capacitance
250°F (121°C)
maximum
Hi-temp Capacitance
325°F (163°C)
maximum
Conductivity
for conductive fluids
12"
A100C12A
A100HC12A
A100CSS12A
24"
A100C24A
A100HC24A
A100CSS24A
36"
A100C36A
A100HC36A
A100CSS36A
48"
A100C48A
A100HC48A
A100CSS48A
60"
A100C60A
A100HC60A
A100CSS60A
72"
A100C72A
A100HC72A
A100CSS72A
84"
A100C84A
A100HC84A
A100CSS84A