Table of Contents Table of Contents
Previous Page  925 / 972 Next Page
Information
Show Menu
Previous Page 925 / 972 Next Page
Page Background

N-9

Technical

DPL417

877.963.4966 •

dixonvalve.com

N

Hose (rubber covered)

1"

1

¼

" 1

½

"

2"

2

½

"

3"

4"

5"

6" Notes

Material Handling

rubber lined

75 75 50 50 50 25 25 (4) bands on 6"; (3) bands on 3" to 5"; (2) bands on 1½" to 2½"

75 75 50 50 50 25 25 (4) bands on 6"; (3) bands on 3" to 5"; (2) bands on 1½" to 2½"

125 75 75 50 50 25 25 (4) bands on 6"; (3) bands on 3" to 5"; (2) bands on 1½" to 2½"

125 75 75 50 50 25 25 (4) bands on 6"; (3) bands on 3" to 5"; (2) bands on 1½" to 2½"

150 125 100 75 75

(5) bands on 3" & 4"; (4) bands on 2" & 2½"; (3) bands on the rest

150 125 100 75 75

(5) bands on 3" & 4"; (4) bands on 2" & 2½"; (3) bands on the rest

250 250 150 125 100 75 75 (3) bands on 6"; (2) bands on the rest

250 250 150 125 100 75 75 (3) bands on 6"; (2) bands on the rest

250 250

125 100

Requires properly matched stem and ferrule.

600 600 600 600 500 450 400

800 800 600 600 500

400 Consult factory for ratings on IXF48-3 to IXF48-5 & IXF64-2 to IXF64-5 ferrules. Internal Expansion is NOT

recommended for XLPE, UHMWPE & Gum Rubber lined hoses.

400

350 300

300 300

230 (13) crimp length would be full length

400

300 250

200 175

75 (13) crimp length would be full length

250

250 250

150 150

75 (13) crimp length would be full length

250

250 250

125 110

75 (13) crimp length would be full length

Material Handling

no helical wire

rubber lined

75 75 50 50 50 25 25 (3) double bolt clamps on 5" & 6"; (2) double bolt clamps on 3" to 4"; (1) double bolt clamp on the rest

125 75 75 50 50 25 25 (3) double bolt clamps on 5" & 6"; (2) double bolt clamps on 3" to 4"; (1) double bolt clamp on the rest

150 125 100 75 75

(3) double bolt clamps on all sizes

400

350 300

300 300

230 (13) crimp length would be full length

400

300 250

200 175

75 (13) crimp length would be full length

250

250 250

150 150

75 (13) crimp length would be full length

250

250 250

125 110

75 (13) crimp length would be full length

Material Handling

cement

rubber lined

600 600 600 600 450 450 250

250 Cement will erode ID

600 600 600 600 600 600 500 450 400 Cement will erode ID

800 800 800 800 600 600 500

400 Cement will erode ID Consult Dixon

®

for ratings on IXF48-3 to IXF48-5 & IXF64-2 to IXF64-5 ferrules.

Petroleum Transfer

125 125 125 75 75 50 50 25 25 (4) bands on 6"; (3) bands on 3" to 5"; (2) bands on 1½" to 2½"; (1) band on the rest

125 125 75 75 50 50 25 25 (4) bands on 6"; (3) bands on 3" to 5"; (2) bands on 1½" to 2½"; (1) band on the rest

150 150 150 125 100 75 75

(5) bands on 3" & 4"; (4) bands on 2" & 2½"; (3) bands on 1¼" & 1½"; (2) bands on the rest

150 150 125 100 75 75

(5) bands on 3" & 4"; (4) bands on 2" & 2½"; (3) bands on the rest

250 250 250 250 150 125 100 75 75 (3) bands on 6"; (2) bands on the rest

250 250 250 150 125 100 75 75 (3) bands on 6"; (2) bands on the rest

250

250 250

125 100

Requires properly matched stem and ferrule.

800 800 800 800 600 600 500

400 Consult factory for ratings on IXF48-3 to IXF48-5 & IXF64-2 to IXF64-5 ferrules.

600 600 600 600 600 600 500 450 400

400

350 300

300 300

230 (13) crimp length would be full length

400

300 250

200 175

75 (13) crimp length would be full length

250

250 250

150 150

75 (13) crimp length would be full length

250

250 250

125 110

75 (13) crimp length would be full length

Air Craft Refueling

conforming toAPI 1529

300 300 300 300 300 300 300

Push-On

Push-On fittings should ONLY be used on Push-On hose.

Steam

250 250 250 250 250 250 250

250

Water

150

(2) bands on

" or larger; Must use mating Dixon

®

Air King™ fittings with safety clip installed. Band & Buckle is

NOT recommended for 1

½

" and smaller.

150

Must use mating Dixon

®

Air King™ fittings with safety clip installed. Band & Buckle is NOT recommended for 1½"

and smaller.

150

(14) Coupling and ferrule are sold separately. Must use mating Dixon

®

Air King™ fittings with safety clip installed.

100

(1) band; Band & Buckle is NOT recommended for 1½" and smaller.

100

100 75 75 75 50 50 50 25 25 (4) bands on 6"; (3) bands on 3" to 5"; (2) bands on 1½" to 2½"; (1) band on the rest

75 75 75 50 50 50 25 25 (4) bands on 6"; (3) bands on 3" to 5"; (2) bands on 1½" to 2½"; (1) band on the rest

150 150 125 75 75 50 50 25 25 (4) bands on 6"; (3) bands on 3" to 5"; (2) bands on 1½" to 2½"; (1) band on the rest

300 300 150 125 100 75 75

(5) bands on 3" & 4"; (4) bands on 2" & 2½"; (3) bands on 1¼" & 1½"; (2) bands on the rest

250 250 250 250 150 125 100 75 75 (3) bands on 6"; (2) bands on the rest

250 250 250 150 125 100 75 75 (3) bands on 6"; (2) bands on the rest

250

250 250

125 100

Requires properly matched stem and ferrule.

600 600 600 600 450 450 250

250

600 600 600 600 600 600 500 450 400

400

350 300

300 300

230 (13) crimp length would be full length

400

300 250

200 175

75 (13) crimp length would be full length

250

250 250

150 150

75 (13) crimp length would be full length

250

250 250

125 110

75 (13) crimp length would be full length

Water

no helical wire

75 75 50 50 50 25 25 (3) double bolt clamps on 5" & 6"; (2) double bolt clamps on 3" to 4"; (1) double bolt clamp on the rest

125 75 75 50 50 25 25 (3) double bolt clamps on 5" & 6"; (2) double bolt clamps on 3" to 4"; (1) double bolt clamp on the rest

150 125 100 75 75

(3) double bolt clamps on all sizes

400

350 300

300 300

230 (13) crimp length would be full length

400

300 250

200 175

75 (13) crimp length would be full length

250

250 250

150 150

75 (13) crimp length would be full length

250

250 250

125 110

75 (13) crimp length would be full length

Pressure Recommendations