B-2
ADS Industrial Fluid
Controls
DPL417
877.963.4966 •
dixonvalve.comB
ADS Outalarms
ADS Outalarm with Capacitance Probe
Application:
•
specifically designed for liquid terminal operation on batch loading and overfill protection, tank
cars, tanks trucks, marine barges, suitable for open and closed dome
Features:
•
totally self-contained; no wires, tubing or external power
•
rugged weather and corrosion resistant construction
•
no moving parts, tip sensitive phase shift™ digital capacitance sensor for conductive and
non-conductive fluid
•
intrinsically safe design per ANSI/UL913 for Class I, Div I Groups A, B, C and D Hazardous
Areas
•
requires no calibration or adjustment
•
operates up to 2500 hours on a single 9V alkaline battery
•
adjustable insertion length through a standard ½" NPT fitting
•
high intensity audible and flashing visual outputs
•
full, hard graduated laser engraved rod
•
fail safe continuous battery monitor goes to alarm state on low battery
•
activation point ¼" above liquid surface
•
24", 36", 48" and 60" probe lengths standard, other lengths available
•
battery current drain <0.23 ma during standby; <50 ma in alarm state
•
horn intensity 101 dB at 2'
•
light output 3 each 3000 mcd high intensity flashing LED's
•
wetted materials: 316 stainless steel, PTFE standard, other materials available
•
pressure rating on standard unit:
50 PSI
, consult Dixon
®
for applications up to 300 PSI
•
optional opto-isolated solid state contact output
ADS Outalarms with Probe
Automated Design Service, Inc. (ADS) is now operating as Dixon
®
Industrial Fluid Control to manufacture products specifically
designed for liquid terminal operations. Our standard product offering is shown on the following pages. However, there are
numerous additional applications, materials and custom designs available. Please call
513.874.8499
or
877.582.3569
for technical information or assistance with ordering these products or scan the QR code
to access our complete catalog.
Probe Length
Part #
Price/E
24"
A100C24A
$3068.20
36"
A100C36A
3068.20
48"
A100C48A
3068.20
60"
A100C60A
3068.20
72"
A100C72A
3295.45
84"
A100C84A
3295.45
96"
A100C96A
3295.45
Features:
•
capacitance Phase Shift probe
•
½" NPT gland standard
•
minimum dielectric constant 1.8
•
temperature range: -
14°F
to
250°F (-26°C