I-48

Valves

DPL417

877.963.4966 •

dixonvalve.com

I

Fire Valves / Building Connections

Domestic Adjustable Pressure Restricting Angle Valves

Global Adjustable Pressure Restricting Angle Valves

Application:

used where flowing water pressure needs to be controlled

Features:

preset orifices restrict the volume of water thereby lowering the pressure of the flowing water;

NFPA requires restricting valves where inlet pressure exceeds 100 PSI

restricting valve has no effect on the static pressure of a system

can be manually by-passed if required by opening the valve fully, this is accomplished by

breaking the breakable link, which allows the valve stem to rise to the full open position

breakable link also serves as an indication of valve condition and status; if valve is opened

without breaking the link it will resume its previous position and no resetting is necessary

restricts inlet pressure from 70 PSI up to a maximum of 175 PSI

restricts down to outlet pressures of 65, 80 or 100 PSI, outlet pressures may be set below 65

PSI when authorized by the local authority having jurisdiction

restricts only under flow conditions

setting charts are packed with valve

UL listed

New York City Board of Standards and Appeals, approval # MEA 54-07-E

maximum operating pressure: up to

175 PSI

aluminum handwheel

other configurations are available, contact Dixon

®

for additional information

Inlet

Female NPT

Outlet

Male NST (NH)

Cast Brass

Part #

Price/E

1½"

1½"

AVAPR150F

$568.95

2½"

2½"

AVAPR250F

802.85

Inlet

Female NPT

Outlet

Female NPT

Cast Brass

Part #

Price/E

1½"

1½"

AVAPRF150

$576.70

2½"

2½"

AVAPRF250

787.40

female x male

female x female

Application:

used when flowing water pressure needs to be controlled

Features:

preset orifices restrict the volume of water thereby lowering the pressure of the flowing water;

NFPA requires restricting valves where inlet pressure exceeds 100 PSI

restricting valve has no effect on the static pressure of a system

restricting device can be manually by passed if required by opening the valve fully: pull the

pin allowing the yoke to fall back from the valve stem which allows valve to be fully opened,

when valve needs to be restricted again, slide the yoke back into place to be NFPA compliant

Inlet

Female NPT

Outlet

Male NST (NH)

Cast Brass

Part #

Price/E

1½"

1½"

AVAPR150F-I

$126.70

2½"

2½"

AVAPR250F-I

268.35

Inlet

Female NPT

Outlet

Female NPT

Cast Brass

Part #

Price/E

1½"

1½"

AVAPRF150-I

$126.70

2½"

2½"

AVAPRF250-I

268.35

female x male