Table of Contents Table of Contents
Previous Page  144 / 932 Next Page
Information
Show Menu
Previous Page 144 / 932 Next Page
Page Background

Air Fittings

142

DPL116

877.963.4966 •

dixonvalve.com

F

Safety Check Valves

Check Valve in

Open Position

Check Valve in

Closed Position

Application:

used in temporary plant/factory air lines, construction sites, shipyards or utilities

not for use in applications where 100% of the available air is required, i.e. sand blast, pile driving rigs,expansion

joint blow down pipes, etc.

Features:

high flow valve provides optimum performance

controls excess air flow (SCFM) in only one direction

automatically senses change in air flow and shuts off the flow in the event of a surge in excess of valve flow rating thus

preventing hose whip

solid brass body and valve

stainless steel spring and roll pin

maximum operating pressure:

250 PSI

maximum temperature:

250°F

does not prevent backflow

Specification:

conforms to OSHA regulation 1926.302 (b) (7) requiring a safety device at the source of the air supply and at branch air lines

How It Works:

Safety check valves utilize the pressure differential across the valve to operate the valve and spring assembly. The pressure

differential is directly related to the flow of air (SCFM) through the valve.

When the pressure differential is within the operating limits - below the cutoff flow - of the unit, the force on the valve exerted

by the spring is greater than that caused by the pressure differential (see "Open Position" graphic above). The valve remains

open and normal operation continues.

When the pressure differential is above the cutoff limit, the force on the valve exerted by the pressure differential is greater

than the force exerted by the spring, and the valve closes (see the "Closed Position" graphic above).

After the repair is made, normal operation is automatically enabled when pressure across the valve equalizes through the

bleeder hole.

The valve spring size can be specified by determining the air flow during normal operation and by estimating the air flow if a

failure or rupture occurs.

Flow Direction

NPT and Hose

ID Size

Part #

Cut-off Flow Rate

(SCFM at 90 PSI)

Price/E NPT and Hose

ID Size

Part # Cut-off Flow Rate

(SCFM at 90 PSI)

Price/E

¼"

SCVL2

23-29

$62.58

1¼"

SCVL10

260-290

$233.05

⅜"

SCVM3

39-47

58.70

SCVM10

300-340

233.05

SCVS3

52-65

58.70

SCVS10

440-500

233.05

½"

SCVM4

70-78

63.03

SCVH10

570-630

233.05

SCVS4

80-96

63.03

1½"

SCVL12

300-360

390.90

¾"

SCVL6

72-88

99.76

SCVM12

470-530

390.90

SCVM6

92-108

99.76

SCVS12

640-720

390.90

SCVR6

112-128

99.76

SCVH12

750-830

390.90

SCVJ6

132-148

99.76

2"

SCVL16

510-590

533.79

SCVS6

160-180

99.76

SCVM16

725-825

533.79

SCVH6

180-200

99.76

SCVS16

900-1050

533.79

1"

SCVL8

165-195

112.82

SCVH16

1100-1200

533.79

SCVM8

220-260

112.82

3"

SCVL24

1200-1400

2266.67

SCVS8

280-320

112.82

SCVS24

2400-2700

2266.67

SCVH8

310-340

112.82

SCVH24

2850-3050

2266.67