Table of Contents Table of Contents
Previous Page  8 / 44 Next Page
Information
Show Menu
Previous Page 8 / 44 Next Page
Page Background

800.355.1991

6

Dixon Bayco 2016

Dry Bulk Products

Products

Dry Bulk

Application:

Designed specifically for use on trailer tanks containing dry bulk products. If a system blockage

were to occur the valves are designed to open to atmosphere to help prevent the tank from

imploding.

Standards:

These valves come with a set vacuum tolerance of +/-0.5 HG, available in 3 body sizes:

•

1½" male NPT outlet (tank connection) x 1½" female NPT inlet (atmosphere)

•

2" male NPT outlet (atmosphere) x 2" female NPT inlet (tank connection)

•

3" female NPT outlet (tank connection) x 3" female NPT inlet (atmosphere)

Materials:

Bayloy body and bronze poppet

Features & Benefits:

•

Available with a variety of vacuum settings, see chart below for model specific available

pressure settings. Customer should request set pressure at time of order.

•

Relieving capacity (SCFM) varies deponent upon model and pressure setting. See chart below,

or for specific relief rates please refer to our website or contact Dixon™.

•

Installed bolt seal deters tampering

•

Bayloy body eliminates thread galling

1120

Valve

Series

Valve Outlet

(Tank Connection)

Valve Inlet

(Atmosphere)

Available Factory

Set Vacuum Range

(HG)

1

Set Pressure

Tolerance (PSI)

Relieving

Capacity

(SCFM)

2

1120/xx

1½" male NPT outlet

(tank connection)

1½" female NPT inlet (atmosphere)

6 to 24

+/- 0.5 HG 175 to 420

2120/xx

2" male NPT outlet

(tank connection)

2" female NPT inlet (atmosphere)

5 to 24

+/- 0.5 HG 280 to 600

3120/xx

3" female NPT outlet

(tank connection)

3" female NPT inlet (atmosphere)

11 to 25

+/- 0.5 HG 700 to 1350

2120

3120

¹ request the required pressure setting when ordering (xx refers to choice of pressure setting)

² relieving capacity (SCFM) varies with set pressure, for specific rates please refer to our website or contact Dixon™

Vacuum Relief Valves

Trailer/Tank Mounted Air Relief Valves

3

Customer adjustable by a further +/- 3 PSI. Settings below 9 PSI are obtainable by turning the valve adjustment screw.

Example for an 8 PSI setting the valve adjustment would be +4/-2, for 7 PSI +5/-1 and for 6 PSI +6/-0.

Settings above 30 PSI are obtainable by turning the valve adjustment screw. Example for a 31 PSI setting the valve

adjustment would be +2/-4, for 32 PSI +1/-5 and for 33 PSI +0/-6

Air Relief Valve Settings

Pressure Relief Valves

Minimum and Maximum Settings

Vacuum Relief Valves

Minimum and Maximum Settings

Valve Series

Factory Setting

Minimum Setting Maximum Setting

2180

2 PSI

25 PSI

A2180

2 PSI

27 PSI

A2180ADJ

3

9 PSI

3

30 PSI

3

2182

3 PSI

24 PSI

A2182

6 PSI

27 PSI

2215

3

12 PSI

3

30 PSI

3

3180

4 PSI

30 PSI

A3180

6 PSI

32 PSI

A3180ADJ

3

9 PSI

3

30 PSI

3

Valve Series

Factory Setting

Minimum Setting Maximum Setting

1120

6" Hg

24" Hg

2120

5" Hg

24" Hg

3120

11" Hg

25" Hg