235
Dixon Sanitary 2016
800.789.1718
Technical
X
Particulate Reference Chart
316 Square Mesh Wire Cloth Information
Perforated 316 Disc Information
1
standard size for clamp style gaskets
2
standard size for bevel seat size gaskets
3
available in only 1", 1½" and 2" sizes
1
standard size for clamp style
Hole
Diameter
Micron
Equivalent
Open
Area
.020"
503
30%
.033"
1
803
28%
.063"
1573
23%
.100"
2517
33%
.125"
3146
40%
.250"
6350
58%
•
1 micron = .00003973 inches
•
special order - minimums apply
•
special order parts, minimum order quantities required
Mesh
Micron
Equivalent
Opening
Width
Wire
Diameter
Openings per
Square Inch
4
5400
.215
.035
16
6
3221
.132
.035
36
8
2441
.097
.028
64
9
2089
.083
.025
81
10
1887
.075
.023
100
12
1510
.050
.023
144
14
1283
.051
.020
196
16
1082
.0455
.016
256
20
855
.034
.016
400
30
427
.017
.016
900
35
422
.0168
.0118
1275
40
377
.015
.010
1600
50
276
.011
.009
2500
60
226
.009
.0075
3600
80
176
.007
.0055
6400
100
151
.006
.0045
10,000
120
120
.0048
.0035
14,400
150
103
.0041
.0026
22,500
200
73
.0029
.0021
40,000
1
2
3
3
3
3