Table of Contents Table of Contents
Previous Page  109 / 292 Next Page
Information
Show Menu
Previous Page 109 / 292 Next Page
Page Background

107

Dixon Sanitary 2016

800.789.1718

Tubing

J

Dixon Sanitary Tubing

Tube OD

Size

Nominal

Wall

Thickness

(inches)

Pressure (

PSI

)

working yield

burst

½"

.065

4,870

7,800 19,500

¾"

.065

3,250

5,200 13,000

1"

.065

2,440

3,900

9,800

1½"

.065

1,630

2,600

6,500

2"

.065

1,220

2,000

4,900

2½"

.065

980

1,600

3,900

3"

.065

810

1,300

3,300

4"

.083

780

1,200

3,100

6"

.109

680

1,090

2,720

304 Stainless Steel Tube

Operating Pressures

Product Specifications

Size range:

½" - 6" OD tube

Materials:

G = 304 stainless steel

R = 316L stainless steel

Finish:

3A sanitary finish ID and OD; Typical 20Ra ID, 32Ra OD

unpolished

BPE finishes are available

Notes:

tubing available in 20' lengths only

surcharges change MONTHLY

broken box charges will apply

tubing only ships via truck

call Dixon Sanitary for pricing and full freight allowance

other sizes may be available, call Dixon Sanitary for

information

tubing is NOT returnable

Tube OD

Size

Nominal

Wall

Thickness

(inches)

Pressure (

PSI

)

working yield

burst

½"

.065

3,250

6,500 19,500

¾"

.065

2,167

4,330 13,000

1"

.065

2,280

3,300

9,100

1½"

.065

1,520

2,200

6,100

2"

.065

1,140

1,600

4,600

2½"

.065

910

1,300

3,600

3"

.065

760

1,100

3,000

4"

.083

730

1,000

2,900

6"

.109

635

900

2,540

316L Stainless Steel Tube

The pressures shown in the table above are calculated using

Barlow's Formula and the following properties:

material: 304

yield strength (

PSI

):

30,000

tensile strength (

PSI

):

75,000

Working Pressure = ¼ of Burst Pressure, these calculate from

-20°F

to

100°F

.

The pressures shown in the table above are calculated using

Barlow's Formula and the following properties:

material: 316L

yield strength (

PSI

):

25,000

tensile strength (

PSI

):

70,000

Working Pressure = ¼ of Burst Pressure, these calculate from

-20°F

to

100°F

.

Index

A270 tubing.................................................................... 108

A269 tubing.................................................................... 108

Tube

OD

Nominal Wall

Thickness

(inches)

Gage

Number

Wt.

Pounds per Ft.

½"

.065

16

0.31

¾"

.065

16

0.49

1"

.065

16

0.67

1½"

.065

16

1.02

2"

.065

16

1.36

2½"

.065

16

1.71

3"

.065

16

2.06

4"

.083

14

3.45

6"

.109

12

6.92

Pipe size and Tube OD size materials are not interchangable

331

33-02