4
Install both die securing bolts
with nuts positioned in opening
of swager plates. Tighten die
securing bolts 1/4 turn past
finger tight.
Caution
When swaging stainless steel
fittings, lubricate through-hole of
dies with ThreadMate™. Failure
to do so may result in damage
to fittings.
Insert both die halves around
hose in each end of swager.
Assembly
5
Assemble hose –
Align
swager plates in parallel
and tighten nuts on swaging
bolts uniformly until dies touch.
Caution
Ensure swager plates remain in
parallel when tightening swager
bolts. Failure to do so will result
in an improperly swaged fitting.
Lubricate –
Using an SAE 20
weight oil, lightly lubricate inside
of both hose ends.
Assembly
6
Remove die securing bolts and
nuts. Then remove dies.
Loosen swaging bolts to release
pressure on dies.
Assemble hose –
Remove
completed hose assembly.
Assembly