Parker Hannifin Corporation
| Parflex
®
Division | Ravenna, Ohio |
For detailed ordering information, please consult price list or contact Parflex
®
Division.
G-23
Hose Assembly & Crimping
PTFE Field Attachable
(
cont.)
Series
90
7
Remove assembly from vise and
reposition with socket in vise
jaws. Ensure socket extends
beyond vise jaws far enough to
allow nipple to be completely
tightened.
Push socket forward and
hand-start threading of socket
to nipple.
Caution
When tightening socket in
vise, do not over tighten vise
jaws. Over tightening vise jaws
will distort internal threads of
socket.
Assembly
8
Wrench tighten nipple hex until
clearance between hex and
socket hex is 1/32" or less.
Tighten further to align corners
of nipple and socket hexes if
necessary.
Assembly
9
Measure and verify hose assembly
length.
Measure & Inspect