A
B
&
C
D
E
&
F
Parker Hannifin Corporation
| Parflex
®
Division | Ravenna, Ohio |
For detailed ordering information, please consult price list or contact Parflex
®
Division.
G
G-17
Hose Assembly & Crimping
Field Attachable
(
cont.)
Series
51,
BU & MS
(
Do not use these fittings on oxygen service lines)
4
Place hex portion of socket into
vise and tighten vise. Ensure
socket extends past vise jaws
enough to allow for installation
of nipple.
Assembly
5
Using an SAE 20 weight lubri-
cating oil, generously lubricate
nipple and socket, threads and
hose I.D.
Using a wrench on the nipple
hex, screw nipple into socket
clockwise until nipple bottoms
against socket shoulder.
Caution
Nipple should be firm when
tightened but not difficult to
turn. If nipple is difficult to install,
check hose for proper lubrica-
tion. Re-apply lubricating oil as
necessary. Installation of nipple
without proper lubrication will
damage core tube.
Assembly
6
Measure and verify hose assembly
length.
Inspection
Caution
When tightening socket in
vise, do not over tighten vise
jaws. Over tightening vise jaws
will distort internal threads of
socket and hamper installation
of nipple.