Parker Hannifin Corporation
| Parflex
®
Division | Ravenna, Ohio |
For detailed ordering information, please consult price list or contact Parflex
®
Division.
G-16
Hose Assembly & Crimping
Field Attachable
Series
51,
BU & MS
(
Do not use these fittings on oxygen service lines)
Fittings –
Inspect socket for
damaged or missing threads.
Do not use if conditions exist.
1
Inspection
Hose –
Visually inspect both
ends of hose for square cut.
Remove any burrs, loose fibers
or wires.
Inspect nipple for a through-
hole, damaged or missing
threads and improperly crimped
nut (if applicable). Do not use if
these conditions exist.
Lubricate –
Using an SAE
20
weight lubricating oil,
lightly lubricate inside and
outside of hose end.
Using a Parker VBS or VBL
(
vise block), place hose in
proper hole of vise block and
place in bench vise. Ensure
enough hose extends from
vise block to install socket.
CAUTION:
There are several different sections
for Hose Assembly and Crimping. Be sure you are
in the section that corresponds to the fitting series
you are using.
See
for listing.
3
Using a wrench, screw socket
onto hose counterclockwise
until it bottoms. Ensure end of
hose is against inside shoulder.
Back off socket 1/4 turn clock-
wise.
Socket should be firm when
tightened but not difficult to turn.
If socket is difficult to install,
apply lubricant that is compat-
ible with the hose material. Do
not use a lubricant with MS
series.
Assembly
Lubrication –
Using an SAE
20
weight lubricating oil, lightly
lubricate inside of hose end.
2
Assembly
Using the Parker VBS or VBL
vise block, place hose in proper
hole of the vise block and then
clamp in a bench vise. Ensure
enough hose extends from the
vise block to install socket.
Caution
Ensure hose is installed
in correct size hole of vise block.
Clamping hose in a smaller hole
will crush hose.