Page 496 - 4300 Catalog Cover.pdf

SEO Version

V10
Parker Hannifin Corporation
Tube Fittings Division
Columbus, Ohio
4300 Catalog
Appendix
Hyferset Pre-Setting Pressures for Ferulok Fittings
1)
Hyferset Pre-Setting
Pressures for EO
Steel Fittings
2)
Pre-Setting Tools
Hyferset Pre-Setting
Pressures for EO-2
Steel Fittings
2)
Table V14 — Pre-Setting Pressures for Ferulok Fittings
1) Ferulok pre-setting dies are positive stop dies. Use of above pressures is optional.
Table V15 — Pre-Setting Pressures for EO Fittings
2) EO and EO-2 pre-setting dies are not positive stop
style. Pre-setting must be done using pressures given
in these charts.
Table V16 — Pre-Setting Pressures for EO-2 Fittings
2) EO and EO-2 pre-setting dies are not positive stop
style.Pre-settingmust bedoneusingpressuresgiven
in these charts.
Tube
Size
Wall Thickness — Steel
Wall Thickness — Stainless Steel
0.035 0.049 0.065 0.083 0.095 0.109 0.120 0.035 0.049 0.065 0.083 0.095 0.109 0.120
4
800
900
1,400 1,800 1,800 1,800
900
1,000 1,500 2,000 2,000 2,000
6
900
1,400
800
2,000 2,000 2,000 2,200 1,000 1,500 2,000 2,000 2,000 2,000 2,500
8
1,600 2,000 2,500 2,700 3,000 3,200
1,800 2,200 3,000 3,000 3,500 3,500
10
2,200 2,700 3,000 3,500 3,500
2,500 3,000 3,500 4,000 4,000
12
2,700 3,000 3,500 3,500 4,000
3,000 3,500 4,000 4,000 4,500
14
3,000 3,500 3,500 4,000 4,500
3,000 4,000 4,000 4,500 5,000
16
3,500 4,000 4,500 5,000
4,500 4,500 5,000 5,000
18
4,000 4,500 4,500 5,000
4,500 5,000 5,000 5,500
20
4,500 5,000 5,500
5,000 6,000 6,000
24
5,500 6,000 7,000
6,500 7,000 7,000
28
7,000 7,500 8,000
7,500 8,000 8,500
32
8,500 9,000 10,000
9,500 10,000 10,000
Pre-Setting Pressures (psi) for EO2 Fittings
Tube
Size (mm)
Wall Thickness (mm)
1.0
1.5
2.0
2.5
3.0
6-L
650
650
6-S
650
650
8-L
900
900
8-S
900
900
10-L
1,350
1,350
1,550
10-S
1,350
1,350
1,550
12-L
1,750
1,750
1,750
1,750
12-S
1,750
1,750
1,750
1,750
14-S
2,000
2,000
2,200
2,200
15-L
1,800
1,800
16-S
2,200
1,450
1,450
18-L
2,000
2,000
2,000
20-S
3,300
3,500
22-L
3,100
3,100
25-S
4,000
4,000
28-L
3,500
3,500
Hyferset
Pre-Setting Pressures (psi)
for EO-2 Fittings
Size Series Any wall
6
L
1,150
6
S
1,150
8
L
1,450
8
S
1,450
10
L
2,450
10
S
2,450
12
L
2,800
12
S
2,800
14
S
3,500
15
L
2,800
16
S
3,900
18
L
3,200
20
S
5,600
22
L
4,950
25
S
6,400
28
L
5,600
Dimensions and pressures for reference only, subject to change.