Page 495 - 4300 Catalog Cover.pdf

SEO Version

4300 Catalog
Appendix
V9
Parker Hannifin Corporation
Tube Fittings Division
Columbus, Ohio
Table V13 — Hydra-Tool Recommended Pre-Setting Pressures for Inch Tube
1) These values are provided as a guide only and normally will produce a satisfactory bite.
2) Ferulok pre-setting dies are positive stop dies. Use of above pressures is optional.
3) For wall thicknesses greater than those liste
Table V12 — Pre-Setting Pressures for Steel and
Stainless Steel EO-2 Fittings
NOTE:
The values provided in this chart are provided as a
guide only and normally will produce a satisfactory bite when
using the Parker Hydra-Tool.
Hydra-Tool Pre-Setting Pressures for EO and EO-2 Steel Fittings
Table V11 — Pre-Setting Pressures for Steel EO Fittings
NOTE:
The values provided in this chart are provided as a guide only and
normally will produce a satisfactory bite when using the Parker Hydra-Tool.
Pre-Setting Tools
Pressures for Steel EO Fittings
Using Stop Adapter (971107 & 971108)
Pressures for Steel EO-2
Fittings Using Stop Adapter
(971107 & 971108)
Hydra-Tool Pre-Setting Pressures for Ferulok Fittings
1) 2) 3)
Tube
Size
Wall Thickness – Steel
Wall Thickness – Stainless Steel
0.035 0.049 0.065 0.083 0.095 0.109 0.120 0.035 0.049 0.065 0.083 0.095 0.109 0.120
4
300
300
500
600
600
600
300
300
500
700
700
700
6
300
500
600
700
700
700
700
300
500
700
700
700
700
800
8
500
700
800
900
1,000 1,000
600
700
1,000 1,000 1,100 1,100
10
700
900
1,000 1,100 1,100
800
1,000 1,100 1,300 1,300
12
900
1,000 1,100 1,100 1,300
1,000 1,100 1,300 1,300 1,500
14
1,000 1,100 1,100 1,300 1,500
1,000 1,300 1,300 1,500 1,600
16
1,100 1,300 1,500 1,600
1,500 1,500 1,600 1,600
20
1,500 1,600 1,800
1,600 2,000 2,000
24
1,800 2,000 2,300
2,100 2,300 2,300
32
2,800 2,900 3,300
3,100 3,300 3,300
Pre-Setting Pressues (psi) for EO Fittings
Wall Thickness (mm)
Size Series 1.0 1.5 2.0 2.5
3.0
4.0
6
L
500 500 500
6
S
500
8
L
500
500
8
S
500 500
10
L
500
10
S
500
12
L
300 300 500
12
S
300
14
S
1,500
15
L
500 800
16
S
1,200
1,300
18
L
1,000
1,300
20
S
2,000
22
L
1,500 1,500
25
S
2,000 2,000
28
L
2,000
30
S
3,000
35
L
3,000
3,300
38
S
3,500
42
L
4,000
Hydra-Tool
Pre-Setting Pressures (psi)
for EO-2 Fittings
in Steel and Stainless Steel
Using the Stop Adapter
Size Series
psi
6
L
1,100
6
S
1,100
8
L
1,300
8
S
1,300
10
L
1,800
10
S
1,800
12
L
2,000
12
S
2,000
14
S
2,300
15
L
2,300
16
S
3,000
18
L
3,000
20
S
4,100
22
L
3,100
25
S
5,500
28
L
3,700
30
S
6,600
35
L
5,300
38
S
8,400
42
L
7,600
Dimensions and pressures for reference only, subject to change.