Diagnostic Products
Quick Coupling Division
8145 Lewis Road • Minneapolis, MN 55427
www.parker.com/quickcouplings
F-4
F
Diagnostic
Meter Selection Guide
Product Selection Guide
Test Port Coupling Selection Guide
Note:
See the Specifications Table for PD and PDP Series for more information.
Valving
Body Material*
Locking
Std. Seal
Temp
Rated
Size Br SS S P Mechanism Material
Range**
Pressure
Test Port
PD Series
Flush Face
1/8"
• • •
Ball
Nitrile
-40° to +250° F
6000 PSI
PDP Series
Ball
1/8"
•
Ball
Nitrile
-40° to +250° F
6000 PSI
EMA3 Series
Poppet
1/8"
• •
Threads Nitrile/Fluorocarbon -15° to +250° F
9000 PSI
* See Fluid Compatibility chart and/or consult factory for questions regarding proper material for specific applications.
CODE: Br = Brass; SS = Stainless Steel; S = Steel; P = Plastic
**Temperature Range for standard seal material.
The Parker
The Parker
The Parker
Function
ServiceJunior
Serviceman
Service Master 450
Pressure Sensing
•
•
•
Flow Sensing
•
1
•
1
Temperature Sensing
•
1
•
2
Rotational Speed Sensing
•
1
•
Auxiliary Sensing
•
Pressure Differential
•
•
Automatic Sensor Recognition
•
•
•
Auto Power Off
•
•
•
Battery Monitoring
•
•
•
Battery Type
AA (2 req’d)
Rechargeable Ni-MH Rechargeable Ni-Cad
PC Compatible (Windows)
•
1
•
1
Minimum/Maximum Memory
•
•
•
Self Contained Memory
•
On-Line Data Transfer
•
•
Text Display (Lines)
2
2
8
Inputs
1
2
6
Data Points (Maximum in Memory)
250,000
Graphic LCD Display
•
•
Hydraulic Power Calculations
•
Volume Calculations
•
Notes:
(1) Additional accessories are required to perform this function.