Inspection
Fittings – Verify ftting series corresponds to the
selected hose. Visually inspect ftting(s) for a
through-hole, threads and damage.
Hose – Visually inspect both ends of hose for square cut. Remove any burrs, loose fbers or wires.
Permanent Fittings
HOSE ASSEMBLY & CRIMPING
PTFE Hose should be taped prior to cutting. Hose
should be cut at center point of taped section.
Using a power hose cutoff saw, cut hose squarely.
1
Cut
NOTE
3
Prep
Assembly
Insertion Depth – Mark hose end with proper insertion depth line. For jacketed PTFE hoses, use a sharp
knife and light pressure to cut back the cover at least the length of the insertion depth of the ftting.
Assemble Hose – Push ftting onto hose slightly and then remove tape. Continue pushing ftting onto hose
until ftting reaches depth insertion mark.
Do not use lubricating oil when installing
fttings on hose used in oxygen service.
When installing fttings on hose used in
oxygen service, lubricate with a non-oil
based soap solution. Failure to do so may
result in an explosion and personal injury
WARNING
Technical