41
Parker Hannifn Corporation
Parfex Division
Ravenna, OH
Catalog Number 4200-M-2
Process Control & Analyzer Systems
CL— Constant Wattage Electric Trace Tubing —
Low Temperature Maintenance
General
Parker CL Constant Wattage Temptrace™ electric
trace tubing consists of a process tube traced with
a constant wattage heating cable, a heat transfer
foil wrap, a nonhygroscopic glass fber insulation
and a black, 105° C rated, fame-resistant PVC
(FR PVC) jacket.
Parker CL Constant Wattage Temptrace™ is
designed for various temperature ranges including:
Freeze protection and viscosity maintenance of
50° F (10° C) at ambient temperatures of- 40°F
(-40° C); and low process temperature maintenance
of 160°F (71.1° C) to 250° F (121.1°C) @ -40°F
(-40°C) to 80° F (26.7° C) ambient conditions.
Standard product has a Maximum Temperature
Rating (MTR*) of 400° F (204.4° C), power-off and
250°F (121.1°C) Power on. See CH-Constant Watt
design for higher temperature ranges.
*Maximum Temperatue Rating is the maximum
allowable temperature of the tracing fuid.
Temperatures in excess of this may damage the
product or alter its performance.
Applications
Analyzer, impulse and instrument lines; small
diameter process lines; stack gas sampling lines; and
utility lines.
Tubing
Type 122 DHP Seamless Copper and 316/316L
Welded and Seamless Stainless Steel, PFA, FEP and
PTFE are standard. Wall thicknesses are available
upon request. For Material Specifcations of metal
tubing, see
Technical Data
in Section of
the catalog. Consult Division for details.
Heat Transfer Foil
An aluminum heat transfer foil for even heat
distribution for precise temperature control.
Insulation
Patented (U.S. Pat. No. 4,285,369) air-spaced, cross
wrapped applied non-hygroscopic fberglass thermal
insulation for minimum heat loss.
Jacket
The tough, black, 105° C rated, fame-resistant PVC
(FR PVC) jacket protects the tubing against corrosive
atmospheres, water, oils, acids, alkalies and most
chemicals. Additional jacket materials are available
upon request. For Material Specifcations of jackets,
see
Technical Data
in Section of the catalog. Consult
Division for additional details.
Testing
Each tube in every length of Parker Temptrace™ is
pressure tested prior to shipment to assure the
instrument engineer a high quality, reliable, trouble-
free product. For Testing Specifcations, see
Technical Data
in Section of the catalog.
Accessories
Accessories are available for electrical
connections, bundle splicing and end terminations.
Accessories for constant wattage bundles are
identifed in this section. Detailed information on
accessories can be found at www.Parfex.com.
Ordering
For information about how to specify and order, see
How-to-Order in the catalog.
NOTE:
It is absolutely necessary to seal the ends against
contamination from moisture and/or corrosive liquids. Parker
Hannifn cannot assume any liability for product damage
caused by moisture from unsealed ends.
Section 3 —
Maintain Temperatures up to 250°F (121°C) and withstand Maximum
Internal Exposure up to 400°F (204°C)