Page 62-63 - LT_3722_v8_MRO.qxp

SEO Version

9
1.
Disassemble and, if necessary, spray all components with Loctite®
7649™
Primer N™. Allow to dry.
2.
Apply a thin coating of Loctite® PST® Thread Sealant to union face.
3.
Apply a band of Loctite® PST® Thread Sealant to male threads.
4.
Assemble parts snugly.
PST
®
Band
PST
®
Band
PST
®
Band
PST
®
Band
PST
®
Band
PST
®
Coating (May be used for new or damaged seat)
PIPE U
NIONS
1.
C
lean parts of contamination. If necessary, spray Loctite®
7649™
Primer N™
onto
threaded parts (male and female). Allow to dry.
Note:
P
rimer is not required for brass parts.
2.
Apply a ban
d of Loctite® PST® Thread Sealant to male threads starting one
to two thread
s from end of pipe.
3.
Assemble parts sn
ugly.
Do not overtighten.
4.
If initial pressure exc
eeds 1000 psi*, wait 30 minutes before pressurizing.
Note:
For stainless stee
l components, use Loctite®
567™
PST® Thread Sealant.
For general purpos
e thread sealing, use Loctite®
565™
PST®
Thread Sealant or Loc
tite® QuickStix™
561™
PST® Pipe Sealant.
For fine filtration system
s requiring zero contamination, use
Loctite®
545™
Thread Sealan
t for hydraulic/pneumatic fittings.
For easier disassembly or large
diameter fittings, use Loctite®
564™
Thread Sealant.
If sealing chemicals or strong acids/b
ases, refer to Fluid
Compatibility Chart (LT-836).
Do not use on oxygen or strong oxidizers (c
hlorine).
For PVC or ABS pipe, use Loctite® No More Leak
s™.
*Depending on conditions
STANDARD FITTINGS – PIPES, HYDRAULIC, OR AIR
THREAD SEALING