can be used for on and off service or throttling
when positive shut-off is necessary
where a low valve profile is necessary
only 90° rotation from open to fully closed (quick opening)
Handle position is a quick indication of whether valve is
open or closed.
full port ball valves do not resist flow
Ball Valve
Butterfly Valve
Gate Valve
Check Valve
Globe Valve
where positive shut-off is necessary
primarily for fully open or fully closed applications
may be used for throttling
only 90° rotation from open to fully closed
lightweight
easy to install
less costly than an iron body gate valve
for fully open or fully closed service - not for throttling
for minimum line pressure drop
for minimum fluid entrapment in the line
for relatively infrequent operation
To control the direction of flow and for quick, automatic
reactions to flow change. Swing check valves are used
when a minimum resistance to flow is required.
Swing check valves are recommended for use in
conjunction with gate valves. They should not be used in a
rapid recycling system such as reciprocating pumps or air
compressor service where they could cause chatter and
damaging vibration.
for regulation (throttling) of flow
for frequent operation; short stem travel reduces operator's
time
where some line resistance is acceptable