373
Appendix
Appendix
Installation & Maintenance
Assemblies
Equipment & Accessories
Fittings
Hoses
Chemical Resistance Tables
The following is a representative list of fluids and manufacturers and a general guideline for
the use and compatibility of Continental ContiTech hose and fittings.
Hose
Fittings and Adapters
Chemical Name
PTFE
(
Teflon®)
CR
(
polychloropene)
NBR
(
Nitrile)
Nitrile/
PVC
CPE
CSM
Urethane
Nylon
Carbon
Steel
Stainless
Steel 304
Stainless
Steel 316
Aluminum
Brass
Hydrogen Peroxide, 90%
X
X
-
-
-
-
-
X
G
E
-
X
Hydrogen Peroxide, Dilute
E
G
-
-
-
-
E
E
-
E
-
X
Hydrogen Sulfide, Aqueous
Solution
G
X
-
-
-
-
-
X
-
-
X
-
Hydrogen Sulfide, Dry, Cold
E
E
-
-
-
-
E
-
-
-
G
X
Hydrogen Sulfide, Dry, Hot
G
X
-
-
-
-
E
E
X
G
G
X
Hydrogen Sulfide, Gas
E
-
-
-
-
-
-
-
-
-
-
-
-
Hydrogen Sulfide, Wet, Cold
(
Permiable )
E
E
X
-
-
-
-
E
G
G
G
G
X
Hydrogen Sulfide, Wet, Hot
E
G
X
-
-
-
-
E
G
G
E
-
X
Hydrogluosilic Acid
Hydrolube, Water Glycol
E
G
E
-
-
-
X
-
X
-
E
-
-
Hydrolubric Oil, Houghton
-
G
-
-
-
G
E
-
-
-
-
-
Hydroquinone
E
X
-
-
-
X
-
-
-
E
E
G
-
Hydroxy Quinoline
Hykil N°6 (33%), Water (67%) E
-
G
-
-
-
-
-
E
-
-
-
-
Hypochlorous Acid,
(
Under 120°F)
X
X
X
-
G
-
E
G
G
G
X
-
Hypoid Grease (Parapoid 10-C)
-
E
-
-
-
-
-
-
-
-
-
-
Imol, Imol S150, S220, S300,
S500
-
E
-
-
-
G
E
E
E
E
E
-
Industron 53
-
E
-
-
-
-
-
-
-
-
-
-
Ink (Printers)
E
E
E
-
-
-
-
E
G
G
E
-
G
Ink Oil
E
-
G
-
-
-
-
-
E
E
E
-
E
Insulating Oil (Transformer)
E
G
E
G
-
X
-
-
E
E
E
-
E
Iodine (Under 100°F)
(
Gas- Permiable )
E
X
X
-
E
G
X
E
G
G
G
X
-
Iodine Pentafluoride
X
X
-
-
-
-
-
X
G
G
X
-
Iodine, in Alcohol
E
G
-
-
-
-
X
-
-
-
-
X
-
Irus Fluid 902
-
E
-
-
-
E
E
E
E
E
E
E
Irus Fluid 905
-
E
-
-
-
E
E
E
E
E
E
E
Isobutane
X
X
-
-
-
X
X
X
E
E
G
E
Isocyanates ( at 70°F)
Isooctane
E
E
G
G
E
G
-
E
E
E
G
E
Isooctyl Thioglucolate
E
-
-
-
-
-
-
-
-
-
-
-
-
Isopropyl Acetate
E
X
X
X
-
X
G
E
G
G
E
X
E
Isopropyl Alcohol
(
Isoprooanol)
E
G
G
G
E
G
G
E
E
E
E
E
G
Isopropyl Ether
E
Isopropylamine
Underline is cover compound rating only. Many factors, such as temperature, concentration and length of exposure, are relevant to how chemical exposure affects the tube and
cover or fitting material. The fluid manufacturers recommended maximum operating temperature should be carefully observed. Exceeding the manufacturer's recommended
maximum temperature can result in fluid breakdown and cause harm or shorten life of tube and cover materials. There may be instances where the hose cover could be adversely
affected by fluids which would not chemically affect the hose tube. Conversely, some fluids with an adverse affect on the tube of the hose may not have a deteriorating effect on
the hose cover. It is recommended that the user test the hose/fluid compatability to their own standards. Since no industry standards exist for chemical resistance, the Compass
Chemical Resistance Guide for Elastomers is used whenever possible. Teflon® is a registered trademark of Dupont.
Rating Scale
E
= Excellent resistance
G
= Good resistance
X
= Not recommended
-
= Testing recommended
Blank