Plylon Plus® Troughability – Minimum Belt Width
Table based on ISO 703 Testing Procedure
Idlers
220/2 250/2 330/3 375/3 400/2 440/4 500/4 600/3 750/3 800/4 900/2 1000/4 1000/5 1200/6 1250/5 1350/3 1800/4
Inches
20
degree
18 18 18 20 18 24 24 24 24 30 24
30 36 42 36 30 36
35
degree
18 18 24 24 24 30 30 30 30 36 30
36 42 48 42 36 42
45
degree
24 24 30 30 30 36 36 36 36 42 36
42 48 54 48 42 48
Millimeters
20
degree
460 460 460 510 460 610 610 610 610 760 610 760 910 1070 910 760 910
35
degree 460 460 610 610 610 760 760 760 760 910 760 910 1070 1220 1070 910 1070
45
degree 610 610 760 760 760 910 910 910 910 1070 910 1070 1220 1370 1220 1070 1220
If top cover and pulley cover are balanced (i.e., 3/16 in.x3/16 in. or 5mm x 5mm) or less than 1/16 in. (2mm) differential (i.e., 3/16 in.x5/32 in. or 4mm x 3mm), add 6 in. (150mm) to the
minimum belt width. 6 in. (150mm) narrower widths are possible if the belt is broken in for an extended period of time fully loaded. Consult your Sales Representative. Additional break-in
time is required when the belt has been stored prior to insulation in ambient temperatures of less than 50°F (10°C).
Above tables are based on top cover gauge equal or greater than the bottom (pulley) cover gauge.
Plylon Plus® Minimum Pulley Diameters
Plylon
Plus
220/2
Plylon
Plus
250/2
Plylon
Plus
330/3
Plylon
Plus
375/3
Plylon
Plus
400/2
Plylon
Plus
440/4
Plylon
Plus
500/4
Plylon
Plus
600/3
Plylon
Plus
750/3
Plylon
Plus
800/4
Plylon
Plus
900/2
#
of Plies
2
2
3
3
2
4
4
3
3
4
2
Inches
Over 80%
Tension
16
16
18
18
16
24
24
24
30
30
30
60%
to 80%
Tension
14
14
16
16
14
20
20
20
24
24
24
40%
to 60%
Tension
10
12
14
14
12
16
18
18
20
20
24
Up to 40%
Tension
10
12
14
14
10
16
18
16
18
18
20
Tails and Snubs 10
12
14
14
10
16
18
16
18
18
20
Millimeters
Over 80%
Tension
410
410
460
460
410
610
610
610
760
760
760
60%
to 80%
Tension
360
360
410
410
360
510
510
510
610
610
610
40%
to 60%
Tension
250
300
300
360
300
410
460
460
510
510
610
Up to 40%
Tension
250
300
300
360
250
410
460
410
460
460
510
Tails and Snubs 250
300
300
360
250
410
460
410
460
460
510
Plylon Plus® HT belts (2/900, 3/1350, 4/1800) require a minimum pulley cover gauge of 1/8 in. (3.18mm) if vulcanized splicing will be used.
Plylon Plus® 1000/4-1800/4 continued on page 19
2015
Heavyweight Conveyor Belts
Plylon Plus®
18