Parker Hannifin Corporation
| Parflex
®
Division | Ravenna, Ohio
For detailed ordering information, please consult price list or contact Parflex
®
Division.
A-34
510
A – Refrigerant Hose
Features
Excellent impulse life
Compatible with most common hydraulic and
refrigeration fluids
Certifications
Meets or Exceeds SAE 100R7 except -2
MSHA Accepted except -4, -5, -6
Construction
Tube: Proprietary nylon blend
Reinforcement: Fiber
Cover: Polyurethane
Operating Parameters
Temperature Range:
-40
°F to +212°F (-40°C to +100°C)
Change in working length @ Rated WPSI: ±3%
Min. Burst Pressure is 4x Max. Working Pressure at 73°F (23°C)
Fittings
51
Series
55 Series –
57
Series –
For Crimp Die Selection charts see pgs
Crimp information can be found online, for most
Parker products, at
Colors
Black
Notes
Perforated cover
51
Series field attachable couplings are not intended for use on
hose that has previously been in service
Part
Number
Nominal
I.D.
Maximum
O.D.
Maximum
Working
Pressure
Minimum
Bend
Radius
Weight
Vac.
Rating
Hg./73˚F
Permanent
Fitting
Series
Field
Attachable
Series
inch mm inch mm psi
MPa inch mm
lbs./ft. kg./mtr.
inch
510
A-2
1/8
3
.34
9
2,500
17.2
0.50
13
.03
.05
28
57
–
510
A-3
3/16
5
.43
11
3,000
20.7
2.00
51
.05
.07
28
55
51
510
A-4
1/4
6
.47
12
2,750
19.0
2.50
64
.05
.08
28
55
51
510
A-5
5/16
8
.57
14
2,500
17.2
3.00
76
.08
.12
28
55
51
510
A-6
3/8
10
.64
16
2,250
15.5
4.00
102
.08
.13
28
55
51
510
A-8
1/2
13
.81
21
2,000
13.8
5.50
140
.13
.20
28
55
51
510
A-12
3/4
19
1.10
28
1,250
8.6
7.50
191
.19
.29
28
–
51
510
A-16
1
25
1.40
36
1,000
6.9
10.00
254
.28
.41
28
–
51
lbs
Applications/Markets
Medium pressure service for both field attachable and permanent fittings
Used with most common refrigerants