Parker Hannifin Corporation
| Parflex
®
Division | Ravenna, Ohio |
For detailed ordering information, please consult price list or contact Parflex
®
Division.
G-10
Hose –
Visually inspect both
ends of hose for square cut.
Remove any burrs, loose fibers
or wires.
Fittings –
Verify fitting series
corresponds to the selected
hose. Visually inspect fitting(s)
for a through-hole, threads and
damage.
1
Inspection
Insertion Depth –
Shown is a
55
series fitting. See Hose Fit-
ting Insertion Values, pg
for insertion depths of fitting
series that do not incorporate an
insertion depth. Mark hose end
with proper insertion depth line.
Lubrication (as required) –
Using an SAE 20 weight lubri-
cating oil, lightly lubricate inside
of hose end.
2
Assembly Prep
Warning
Do not use lubricating oil when
installing fittings on hose used in
oxygen service. When installing
fittings on hose used in oxygen
service, lubricate with a non-oil
based soap solution. Failure to
do so may result in an explosion
and personal injury when hose
is used.
Assemble hose –
Push hose
into fitting all the way to depth
insertion mark. (If fitting does not
readily slide onto hose, perform
the next step.)
3
Assembly
Using Parker VBS or VBL (vise
blocks) and a rubber mallet, tap
fitting onto hose until bottom of
fitting shell is aligned with depth
insertion mark.
Permanent Crimp
Series
54, 55, 58, 58
H, 92, CY, HY, LV, MS, SF
Hose Assembly and Crimping
CAUTION:
There are several different sections for Hose Assembly
and Crimping. Be sure you are in the section that corresponds to
the fitting series you are using.
See
or listing.