A
B
&
C
D
E
&
F
Parker Hannifin Corporation
| Parflex
®
Division | Ravenna, Ohio |
For detailed ordering information, please consult price list or contact Parflex
®
Division.
G
G-7
Hose
Part
Number
Volumetric Expansion
at Maximum Working
Pressure
Equation for Volumetric
Expansion
(
psi)
(
cc/ft)
Y=(cc/ft) X=(psi)
575
X-3
5000
1.69
Y = 0.0003x + 0.2119
575
X-4
5000
2.05
Y = 0.0003x + 0.5601
575
X-6
5000
2.71
Y = 0.0004x + 0.8412
575
X-8
5000
4.59
Y = 0.00064x + 1.41795
575
X-12
5000
12.52
Y = 0.00192x + 2.92038
575
X-16
5000
16.81
Y = 0.0028x + 2.9560
590-3
5000
0.646
Y = 0.00013x + 0.01692
590-4
5000
0.888
Y = 0.00016x + 0.09821
590-6
4000
1.87
Y = 0.00038x + 0.32317
590-8
3500
2.17
Y = 0.00049x + 0.43765
590-10
3000
3.69
Y = 0.00095x + 0.82449
590-12
2500
4.20
Y = 0.0013x + 0.8216
590-16
2000
6.21
Y = 0.0026x + 1.0558
D604
3000
1.80
Y = 0.00044x + 0.51607
D606
3000
2.00
Y = 0.0006x + 0.2892
D608
3000
2.88
Y = 0.00057x + 1.20744
D610
3000
2.08
Y = 0.00061x + 0.23127
D612
3000
5.53
Y = 0.00142x + 1.21743
D616
3000
7.33
Y = 0.00205x + 1.24905
H604
3000
1.80
Y = 0.00044x + 0.51607
H605
3000
1.35
Y = 0.00036x + 0.26536
H606
3000
2.00
Y = 0.0006x + 0.2892
H608
3000
2.88
Y = 0.00057x + 1.20744
H610
3000
2.08
Y = 0.00061x + 0.23127
H612
3000
5.53
Y = 0.00142x + 1.21743
The actual volumetric expansion
achieved is influenced by multiple vari-
ables including fluid properties, hose
routing and application temperature.
The volumetric expansion calculation
is only a general guideline and must be
verified by actual testing in the end-use
application. No performance warranty
in design is expressed or implied by this
calculation. Parker recommends that
the user review and understand all the
precautions listed in the Parker Safety
Guide for Selecting and Using Hose, Fit-
tings and Accessories, bulletin
BUL. 4400-b.1.
Volumetric Expansion of Hose
(
cont.)