132
Dixon Sanitary 2014
800.789.1718
Instrumentation
N
Sanitary RTDs & Temperature Transmitters
temperature transmitter
sanitary RTD
Product Specifications
316
L wetted surfaces
exterior surfaces 316L with a near mirror finish
standard 12mm industrial connector with gold plated
contacts for maximum corrosion resistance and cleanability
sensor elements are accurate up to +/-0.1C
RTD – temperature range: -58°F to 392°F
TT – temperature range: -22°F to 302°F
1-1/16"
(
27
mm
)
3½"
(
89
mm
)
RTD-20GI-38
1-13/16"
(
46
mm
)
3½"
(
89
mm
)
1-7/8"
(
48
mm
)
TT-20-G1
Note: custom lengths are available