16
PLYLON PLUS ELEVATOR DATA - Imperial
PLYLON PLUS MINIMUM PULLEY DIAMETERS (in.)
Plylon Plus rated belt tension can exceed 100%, with a maximum of 150%, during starting and stopping conditions. Fastener size recommendation may vary due to cover
thickness, pulley diameters and system tension. Consult your GTM or fastener manufacturer.
Consult your GTM for vulcanized splice design for 900/2, 1350/3, and 1800/4 constructions.
*
P/P = Poly/Poly P/N = Poly/Nylon
Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
250/2
375/3
400/2
500/4
600/3
750/3
800/4
900/2
1000/4 1000/5
1200/6 1250/5
1350/3
1800/4
Number of Plies
2
3
2
4
3
3
4
2
4
5
6
5
3
4
Fabric Type*
P/N
P/N
P/P
P/N
P/P
P/N
P/P
P/N
P/N
P/P
P/P
P/N
P/N
P/N
Industrial Service tension Capacity (piw)
195
290
310
385
465
580
620
700
775
775
930
970
1050
1400
Nom. Carcass Gauge (in.)
0.129
0.169
0.178
0.229
0.251
0.246
0.340
0.314
0.337
0.429
0.518
0.427
0.490
0.636
Nom. Carcass Weight (lbs/sq.ft.)
0.76
1.01
1.00
1.36
1.40
1.50
1.89
1.88
2.04
2.39
2.89
2.59
2.93
3.82
Approx 1/32" cover wt (lbs/sq.ft.)
0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.19
Ave. Elastic modulus (piw)
30,000 45,000 44,000 60,000 66,000 56,250 88,000 62,532 74,000 110,000 132,000 92,500 93,798 125,064
Recommended Plate Fastener
190
BR-10 BR-10
BR-10 BR-10
BR-14
BR-14
NR
NR
NR
NR
NR
NR
NR
Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
250/2
375/3
400/2
500/4
600/3
750/3
800/4
900/2
1000/4 1000/5
1200/6 1250/5
1350/3
1800/4
Number of plies
2
3
2
4
3
3
4
2
4
5
6
5
3
4
Over 80% Tension
16
18
18
24
30
30
36
36
36
42
48
48
42
48
60%
to 80% Tension
14
16
16
22
24
24
30
30
30
36
42
42
36
42
Up to 60 % tension
12
14
14
20
20
20
24
24
24
30
36
36
30
36
PLYLON PLUS MAXIMUM BUCKET PROJECTION (in.)
Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
250/2
375/3
400/2
500/4
600/3
750/3
800/4
900/2
1000/4 1000/5
1200/6 1250/5
1350/3 1800/4
Number of plies
2
3
2
4
3
3
4
2
4
5
6
5
3
4
Spaced Industrial Max. Bucket Projection
7
8
9
11
10
10
11
11
12
12
12
12
13
15
Continuous Industrial Max. Bucket Projection
6
8
9
11
12
12
14
14
15
16
20
20
22
26
P L Y L O N
P L U S
®
E L E V A T O R D A T A
Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon Plylon
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus
Plus Plus
250/2 375/3 400/2 500/4 600/3 750/3 800/4 900/2 1000/4 1000/5 1200/6 1250/5 1350/3 1800/4
Number of plies
2
3
2
4
3
3
4
2
4
5
6
5
3
4
Over 80% Tension
16
18
16
24
24
30
30
30
36
36
42
42
36
42
60%
to 80% Tension
14
16
14
20
20
24
24
24
30
30
36
36
30
36
40%
to 60% Tension
12
14
12
18
18
20
20
24
24
24
30
30
30
36
Up to 40% Tension
12
14
10
18
16
18
18
20
20
20
30
24
24
30
Tails and Snubs
12
14
10
18
16
18
18
20
20
20
30
24
24
30
PLYLON PLUS MINIMUM PULLEY DIAMETERS (in.)
Plylon Plus HT belts (2/900, 3/1350, 4/1800) require a minimum pulley cover gauge of 1/8" if vulcanized splicing will be used.