Technical Information
DPL413
V
877.963.4966 • dixonvalve.com
716
Feet Head of Water to PSI
•
One foot of water at 62°F = 0.433 PSI, to find the PSI for any feet head not given in the table, multiply the feet head by 0.433.
Air Supply Requirements
(operating pressure - 90 PSI)
Tool
Class
Typical Air Consumption (CFM)
Hose Size (inches)
0-10 ft.
10-50 ft.
50-200 ft.
Paving Breakers
25 lb.
35 lb.
60 lb.
80 lb.
45
50
65
80
1/2
1/2
1/2
3/4
1/2
3/4
3/4
3/4
3/4
3/4
1
1
Claydiggers
45
1/2
1/2
3/4
Hand Drills
8 lb.
15 lb.
20
32
3/8
3/8
3/8
1/2
1/2
1/2
Rock (Sinker) Drills
45 lb.
55 lb.
105
130
3/4
3/4
3/4
1
1
1
Tampers
5" butt
6" butt
20
30
3/8
1/2
1/2
1/2
1/2
3/4
Sump Pump
Sludge Pump
3 HP
Ejector
100
90
3/4
1
3/4
1
1
1
Vibrators
2-1/2"
3"
60
60
1
1
1
1
1
1
Chipping Hammers
25
3/8
1/2
1/2
Impact Wrenches
3/8" sq. dr.
1/2"
3/4"
1"
10
15
25
50
5/16
5/16
3/8
1/2
3/8
3/8
1/2
3/4
3/8
1/2
1/2
3/4
Drills
1/4" - 1/2"
22
3/8
3/8
1/2
Grinders
die/burr
small angle
3 HP vertical
20
20
75
3/8
3/8
1/2
3/8
3/8
3/4
1/2
1/2
1
Feet Head Pounds per
Square Inch
1
0.43
2
0.87
3
1.30
4
1.73
5
2.17
6
2.60
7
3.03
8
3.46
9
3.90
10
4.33
Feet Head Pounds per
Square Inch
15
6.50
20
8.66
25
10.83
30
12.99
40
17.32
50
21.65
60
25.99
70
30.32
80
34.65
90
38.98
Feet Head Pounds per
Square Inch
100
43.31
110
47.64
120
51.97
130
56.30
140
60.63
150
64.96
160
69.29
170
73.63
180
77.96
200
86.62
Feet Head Pounds per
Square Inch
250
108.27
300
129.93
350
151.58
400
173.24
500
216.55
600
259.85
700
303.16
800
346.47
900
389.78
1000
433.00
Applied
Pressure
PSI
Nominal Standard Pipe Size
1/8"
1/4"
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
5
0.5
1.2
2.7
4.9
6.6
13
27
40
80
135
240
10
0.8
1.7
3.9
7.7
11.0
21
44
64
125
200
370
20
1.3
3.0
6.6 13.0 18.5
35
75
110
215
350
600
40
2.5
5.5 12.0 23.0 34.0
62
135
200
385
640 1100
60
3.5
8.0 18.0 34.0 50.0
93
195
290
560
900 1600
80
4.7 10.5 23.0 44.0 65.0
120
255
380
720 1200 2100
100
5.8 13.0 29.0 54.0 80.0
150
315
470
900 1450 2600
150
8.6 20.0 41.0 80.0 115.0
220
460
680 1350 2200 3900
200
11.5 26.0 58.0 108.0 155.0
290
620
910 1750 2800 5000
250
14.5 33.0 73.0 135.0 200.0
370
770 1150 2200 3500 6100
Maximum Recommended Air Flow (SCFM)
Through ANSI Standard Weight Schedule 40 Metal Pipe
•
Flow values in the table below are based on a pressure drop of 10% of the applied pressure per 100 feet of pipe for 1/8",
1/4", 3/8", and 1/2" pipe sizes; and a pressure drop of 5% of the applied pressure per 100 feet of pipe for 3/4", 1", 1-1/4", 2",
2-1/2", 3" pipe sizes. The table gives recommended flows for pipe sizes at listed pressures and should be used to determine
appropriate piping for air systems.