General Application Gasketing
KLINGERSIL® C-4201
• Synthetic Fiber
• Nitrile Binder
• Excellent Resistance to Oil & Solvents
• Good Anti-Stick Properties
• Excellent OEM Material
Typical values refer to 1/16" material
unless otherwise specified.
See graphs for temperature & pressure limits
Creep Relaxation
ASTM F38B (1/32")
20%
Sealability
ASTM F37A (1/32")
<0.5 ml/hr
Gas Permeability
DIN 3535/6
<0.5 ml/min
Compressibility
ASTM F36J
7%
Recovery
ASTM F36J
50% minimum
Klinger Hot Compression Test
Thickness Decrease 73°F (23°C)
11% initial
Thickness Decrease 572°F (300°C)
19.5% additional
Weight Increase
ASTM F146 after immersion in Fuel B
5h/73°F (23°C)
10% maximum
Thickness Increase
ASTM F146 after immersion in
ASTM Oil 1, 5h/300°F (149°C)
0-5%
ASTM Oil IRM903, 5h/300°F (149°C)
0-5%
ASTM Fuel A, 5h/73°F (23°C)
0-5%
ASTM Fuel B, 5h/73°F (23°C)
0-5%
Dielectric Strength
ASTM D149-95a
14 kV/mm
ASTM F104 Line Call Out
F712121B3E11K6M5
Leachable Chloride Content
FSA Method (Typical)
200 ppm
Density
ASTM F1315
119 lb/ft 3 (1.9 g/cc)
Color
(Top/Bottom)
White or Black
Pressure & Temperature Graphs