KSRCA0208
17
used in sheet rubber
Sheet Rubber Tolerances
(Tolerances conform to RMA standards, Durometer ± 5 points.)
Thickness
Tolerance
1/32" but not including 1/16".........................± .012"
1/16" but not including 1/8"...........................± .016"
1/8" but not including 3/16"...........................± .020"
3/16" but not including 3/8"...........................± .031"
3/8" but not including 9/16"...........................± .047"
Thickness
Tolerance
9/16" but not including 3/4"...........................± .062"
3/4" but not including 1". ...............................± .094"
1" and Over..................................................... ± 10%
Width
Tolerance
36" and over...................................................± 1.00"
Neoprene
Nitrile
EPDM
SBR
CI
Pure Gum
Silicone
Viton
Hypalon
Heat Aging
Good
Good
Excellent
Good
Good
Good
Excellent
Excellent
Good
Abrasion Resistance
Excellent
Excellent
Very Good
Good
Good
Excellent
Poor
Fair
Fair
Compression Set
Fair
Fair
Fair
Good
Good
Good
Fair
Good
Good
Resilience
Excellent
Good
Good
Good
Good
Outstanding
Fair
Fair
Fair
Tear
Good
Good
Good
Fair
Good
Good
Good
Fair
Fair
Flame Resistance
Excellent
Poor
Very Poor
Very Poor
Very Poor
Very Poor
Fair
Good
Good
Weathering
Very Good
Fair
Excellent
Fair
Fair
Fair
Good
Excellent
Excellent
Ozone Resistance
Very Good
Very Poor
Good
Fair
Fair
Poor
Good
Excellent
Excellent
Gas Permeability
Good
Good
Good
Good
Good
Good
Poor
Poor
Poor
Resistance
Oil Resistance
Good
Very Good
Very Poor
Poor
Poor
Very Poor
Fair
Good
Fair
Gas Resistance
Good
Excellent
Very Poor
Poor
Poor
Very Poor
Poor
Poor
Poor
Acid Resistance
Good
Good
Good
Fair
Fair
Good
Poor
Good
Good
Alkali Resistance
Good
Good
Good
Fair
Fair
Good
Poor
Good
Good
TAKE NOTE!
The general properties shown in the chart above are not intended to be used to
make fnal choices for a specifc application. Exposure to heat, sunlight, chemicals,
ozone and oils, as well as pressure, tension, binding, stretching and folding, will
affect the performance of a rubber product.
Suitability must be determined by a qualifed person. See Cautionary Statement on
the next page.