Tube Fittings Pressure Drop
Inhydraulicsystems, pressuredrop represents lossof energyand
therefore should be kept to a minimum. Pressure loss in straight
tubing and hose is mainly caused by the frictional resistance
of the walls, while in fittings it is mainly caused by changes in
the magnitude or direction of the fluid velocity. Mathematical
analysis of pressure drop, even though possible, may not be
exact because of the interrelationship of factors such as fluid
density, velocity, flow area and frictional co-efficients.
The following pressure drop charts were derived from actual
test data and may be used as a guide for determining pressure
Examples:
drops at various flow rates through fittings for fluid indicated. To
determine pressure drop for a given flow, trace a vertical line up
from the flow axis to the desired size line then trace a horizontal
line from this intersection over to the pressure drop axis.
Example:
A size 8 CTX, with oil, similar to the test fluid, flowing
through it at 4 gallons per minute, would cause a pressure drop
of approximately 2.3 psi. Conversions will have to be made for
fluids which are not similar to test fluid.
The Tube Fittings part numbers are listed below the Pressure
Drop Chart to which they apply.
Fig. U2 — Pressure Drop Chart for 90° Fittings or Branch Path Through a Tee or Cross Fitting (Triple-Lok)
Pressure Drops for Other Fitting:
*These pressure drop curves were established with Triple-Lok fittings. The pressure drop values can be adjusted for other
fittings of the same size by multiplying the value from the chart by the ratio of Triple-Lok flow diameter to that of the other
fitting, raised to the 4
th
power.
Example:
Find pressure drop for 6C5L at 5 gallons per minute flow rate:
From the chart, the pressure drop for 6C5X is 10 psi.
Also, the ratio of 6C5X to 6C5L flow diameters is 0.297/0.264, or 1.125.
Therefore, the pressure drop for Seal-Lok = 10 x (1.125)
4
= 16 psi.
Pressure Drops for Other Fluids:
Pressure drop through a fitting is mainly caused by change in direction and velocity of the fluid. Therefore, it is directly propor-
tional to the specific gravity of the fluid. The drop due to friction, which is dependent on the viscosity of the fluid, is so small in
this case that it can be ignored. Thus, the pressure drop with a different fluid can be calculated by multiplying the value from
the graph above by the ratio of specific gravity of the two fluids, or:
New Drop = Value from the graph x Specific Gravity of New Fluid
Specific Gravity of Test Fluid (0.873)