The SensoControl
®
Service Master
Technical Data
Meter
• Digital LCD Text Display
- 128x64 pixels
• Automatic Character Height Scaling
• Display of Pressure, Temperature,
Flow and Rotational Speed
- Pressure in PSI and Bar
- Temperature in °F and °C
- Flow in GPM and l/min.
- Rotational Speed in RPM
Inputs
• Six, 5-pin push-pull style
connectors
• Automatic Sensor Recognition
• 0-3 Volts (R=470 k
)
• 12 Bit A/D Converter
• 1 ms Scanning Rate (1-3 inputs)
• 2 ms Scanning Rate (4-6 inputs)
Functions
• Differential Value Measurement
• MIN/MAX Memory
• Online data transfer
• Battery level indicator
• Power calculation (display only)
• Flow run-out (display only)
• Auto power off
Output
• RS232 interface
• Adjustable baud rate up
to 38400 BPS
• 8 data bits, 1 stop bit
Power Requirements
• Internal 7.2-volt rechargeable
Ni-Cad battery
• Recharge circuit for use with
external power supply.
• Operating time (Aprox. 5 hours)
• Excitation voltage (12-30 VDC)
Memory Functions
• Memory capacity
250,000 data points
• Memory used in 25,000 data
point intervals
• Variable storage rate
• Variable measuring period
up to 100 hours
• Manual and automatic triggering
Ambient Conditions
• Operating Temperatures
32°F to 122°F (0°C to 50°C)
• Storage Temperatures
-4°F to 140°F (-20°C to 60°C)
• Protection class IP54
Housing
• Glass reinforced polyamide
• 11-Key tactile touch membrane
• EMC Protection
- Electromagnetic interference
(DIN/EN 50081, Part 1)
- Immunity to emitted interference
(DIN/EN 50082, Part 2)
Dimensions
• Length/Height/Width
- 9.25 x 4.19 x 2.09
- (235 x 106 x 52 mm)
Weight
• 1.2 lbs (700 grams)
Function Descriptions
1 ON/OFF
Turns meter on or off
2 SETUP/OPTION
Change system settings
3/4 ARROWS
Select line and function values
5 START/ENTER
Change function values and start measurements
6 STOP/ESC
Stop or terminate functions
7 I1-I2
Differential value between input 1 and input 2.
8 TEMP
Displays the measured temperature values for all channels
9 DATA-OUTPUT
Displays output to PC, printer or graphic display
10 RECORD
To record and store measurements
11 MIN/MAX/ACTUAL
Displays the minimum, maximum and
actual values. Reset deletes values
12 INPUTS
Inputs for up to (6) sensors
13 11-30 VDC
Input for external power supply and charging
of internal battery
14 DATA OUTPUT
RS232 port for connecting to the PC, printer,
or external trigger module
15 GRAPHIC LCD
Displays measured values, adjustment menus
and graphics.
16 ADDITIONAL LINE
Displays the power or flow runout values.
17 STATUS LINE
Shows the designation of the measured value
or the menu name.
ON/OFF
STOP
ESC
START
ENTER
DATA
OUTPUT
SETUP
OPTION
RECORD
TEMP
|1 - |2
|1 = |2
MIN/MAX
ACTUAL
RESET
The Service Master
5
10
3
2
11
7
6
9
1
13
16
15
17
14
12
4
8
Technical Data