518C
PARFLEX 518C
518C - Non-Conductive Hose
SAE J517 ANSI A92.2
Meets or Exceeds SAE 100R7
1000 to 3000 PSI
Part
Number
I. D.
Max.
O. D.
Max.
Working
Pressure
ANSI A92.2
Max.
Working
Pressure
SAE 100R7
Min.
Bend
Radius
Weight
Crimp
Fitting
80C
Crimp
Die
Field
Attachable
Fitting
hose
inch mm inch mm wpsi
MPa wpsi
MPa inch mm lbs/ft
kg/m series pg crimp die re
pg
518C-2
1/8 3 0.34 9 3000 20.68 2500 17.24 1/2 13 .031 .046
57 53-77
P02H N/A
518C-3
3/16 5 0.42 11 3000 20.68 3250 20.68 3/4 19 .046 .069
55 53-77
P03
**
518C-4
1/4 6 0.47 12 3000 20.68 3000 18.96 1-1/2 38 .052 .077
55 53-77
P04J
**
518C-5
5/16 8 0.57 14 3000 20.68 2500 17.24 1-3/4 44 .075 .112
55 53-77
P05
51 42-50
518C-6
3/8 10 0.63 16 3000 20.68 2250 15.51 2
51 .096 .143
55 53-77
P06
51 42-50
518C-8
1/2 13 0.81 21 3000 20.68 2250 15.51 3
76 .148 .221
55 53-77
P08
51 42-50
518C-10 (+)
5/8 16 0.98 25 2000 13.8 1500 10.34 4
102 .200 .298
58 78-102 P10H N/A
518C-12
3/4 19 1.08 27 1660 11.4 1250 8.62
6
152 .188 .280
55 53-77
P12
51 42-50
518C-16
1
25 1.32 34 1330 9.2 1000 6.90
8
203 .269 .401
55 53-77
P16
51 42-50
Note:
The above hose(s) are not intended for use in static discharge applications; i.e., airless paint spray.
(+) Non Standard. See page ii for information on non-standard products.
Tube:
Polyester
Reinforcement:
Fiber
Cover:
Proprietary Blend (PFX)
Cover Color:
Orange, non-perforated
Temperature Range:
-40°F to +212°F
(
-40°C to +100°C)
(Limited to +135°F (+57°C) for synthetic hydraulic fluids and water-based fluids)
Vacuum Rating:
N/A
(Delta) Working Length @ Rated WPSI:
±2% Max.
Applications/Markets:
Medium pressure hydraulic service where both field attachable
and permanent hydraulic circuit exposure and contact with high
voltage may be encountered
Special Features:
Twin or multi-line constructions available
Meets SAE J517 for less than 50 micro-amps leakage under
75,000 volts per ft. Meets or exceeds SAE 100R7 specifications
and Ontario Hydro electrical standards
Complies with ANSI A92.2 for vehicle-mounted aerial devices.
High density braid for maximum impulse life without loss of
flexibility
Note:
Lay lines on this hose will have both ANSI and SAE
maximum working pressures listed. ANSI A92.2-1990 "Vehicle
Mounted Elevating and Rotating Aerial Devices."
** 3/16" and 1/4" working pressure reduced to 3,000 and 2,750
respectively when using field attachable (51 series) couplings.
Min. Burst Pressure:
4:1 Design Factor is required if hose failure will result in
movement of aerial device.
3:1 Design Factor is acceptable if hose failure will not result in
movement of aerial device.
SAE requires 4:1 Design Factor.