Page 5 - ParkerMULTITUBE

SEO Version

Parker Hannifn Corporation
Parfex Division
Ravenna, OH
Chemical Processing and Refneries
Catalog Number 4200-M-2
Introduction:
Parfex Temptube
®
Preinsulated tubing is thermally
insulated with a non-hygroscopic inorganic fberglass
material and protected with a fexible black fame-
resistant PVC jacket.
Performance Data:
Parfex standard Temptube
®
is thermally insulated for
transfer of fuids or gases up to 400°F (204°C) while
maintaining an outer jacket surface temperature of
140°F (60°C), meeting NEC Personnel Protection Code
427.12.
Insulated bundles rated up to 1200°F (649°C) are
available upon request. Contact Parker Hannifn for
more details.
Tubing is available in many alloys and sizes, including
metric size. See “How to Order” for specifying part
numbers to meet your application.
Temptube
®
Preinsulated Tubing
General:
Parker Temptube
®
is designed to provide an
economical and highly effcient method of conveying
steam or other hot materials through a plant and is
intended to replace hard piping and feld-installed
insulation.
Applications:
The Temptube
®
products are typically used in steam
supply lines, condensate return lines, cooling water
lines, lubrication lines, refrigeration lines, and liquid
nitrogen lines.
Tubing:
Type 122 DHP Seamless Copper and 316/316L
Welded and Seamless Stainless Steel are standard.
Additional materials and wall thicknesses are available
upon request. For material specifcation of metal
tubing, see technical data section of the catalog.
Consult Division for details.
Insulation:
Patented (U.S. Pat. No. 4,285,369) air-spaced, cross
wrapped applied non-hygroscopic fberglass thermal
insulation for minimum heat loss. Optional insulation
thicknesses are available; such as, 0.36”, 0.72” and
0.96” insulation used in Cryogenic, Liquid CO2 and
Liquid Nitrogen applications, see Performance Chart
for heat gain rates. For other thicknesses consult
factory.
Jacket:
The tough, black, 105°C rated, fame-resistant PVC
(FR PVC) jacket protects the tubing against corrosive
atmospheres, water, oils, acids, alkalies and most
chemicals. Additional jacket materials are available
upon request. For jacket material specifcations, see
the Technical Data section of the catalog. Consult
Division for additional details.
Testing:
Each tube in every length of Parker Temptube
®
is pressure tested prior to shipment to assure the
instrument engineer a high quality, reliable, trouble-
free product. For Testing Specifcations, see Technical
Data Section of the catalog.
Accessories:
Accessories are available for connecting multiple
lengths of Temptube bundles and sealing bundle
ends.
NOTE:
It is absolutely necessary to seal the ends against
contamination from moisture and/or corrosive liquids. Parker
Hannifn cannot assume any liability for product damage caused by
moisture from unsealed ends.
Section 1