24
Parker Hannifn Corporation
Parfex Division
Ravenna, OH
SH – Self-Regulating High Temperature
Maintenance Bundles
General
Parfex Temptrace
TM
tubing is thermally insulated with a
non-hygroscopic inorganic fberglass material
and protected with a fexible black fame-resistant
PVC jacket.
Parfex standard Temptrace
TM
is thermally insulated
for transfer of fuids or gases up to 400°F (204°C) while
maintaining an outer jacket surface temperature of
140°F (60°C), meeting NEC Personnel Protection
Code 427.12.
SH- Temptrace
TM
is designed to provide temperature
maintenance for gases, liquids or other process
materials. The high temperature self-regulating product
has a maximum temperature rating of 250°F (121.1°C),
power-on, and can be steam cleaned at 400°F (204°C),
power-off and is T3 rated for 3, 5 & 8W. T2D 10, 15, 20W.
SH- Temptrace
TM
can maintain process tube
temperatures up to 250°F (121.1°C), depending upon
ambient conditions.
Heating Cables
Cables are available in 120V and 208-277 volt, with
Heat outputs of 5, 10, 15 and 20 watt/ft.
Parfex standard SH designs all come with an internal
tinned copper braid on heating cable for grounding
purpose and a Fluoropolymer jacket over the heating
cable to provide additional protection against many
harsh environments.
Common Tube Materials and Sizes
Temptrace
TM
is readily available in 1/4”, 3/8” and 1/2”
sizes as well as metric sizes. (6 mm, 8mm, 10mm
and 12mm) The most common stock alloys are
copper type #122 DHP seamless ASTM B68, B75, as
well as seamless and welded stainless steel tubing
316/316L ASTM A269. Many other alloys, ASTM
standards and sizes are available upon request. (See
Technical Data Section)
Testing
All Temptrace
TM
products are pressure tested prior
to shipment. Third party testing and witnessing is
available upon request, including DNV, ABS and
Lloyd’s Register. Contact factory for complete details.
Jacketing Materials
Black UV resistant FR-PVC is our standard material,
however other jacketing materials are available upon
request, including non-halogenated FR-TPE and
Urethanes. (See Technical Data Section)
NOTE: It is absolutely necessary to seal the ends against
contamination from moisture and/or corrosive liquids. Parker
Hannifn cannot assume any liability for product damage caused by
moisture from unsealed ends.
Maintain Temperatures up to 250°F (121°C) and withstands an Internal
Exposure Temperature of 400°F (204°C)
Catalog Number 4200-M-2
Chemical Processing and Refneries