Product
Connection
Body
Seal
Working Pressure at 73° (psi) Temperature
Category
Technology
Material
Material
(1/4 Burst Pressure)
Range (F)
Full stainless
steel gripping ring Engineered
High-
Push button
Performance
LIQUIfit
release
Nylon
EPDM
230
†
N/A 190
†
160
†
+35° to +200°
Acetal
EPDM
300
†
300
†
300
†
N/A
-20° to +180°
Collet
Polypropylene
EPDM
150
†
N/A 150
†
N/A
0° to +225°
Push button
TrueSeal
release
Kynar
Fluorocarbon 300
†
N/A 300
†
N/A
0° to +275°
Full stainless
steel gripping ring Polypropylene
Nitrile
300
†
300
†
250
†
200
†
0° to +212°
Fast&Tite
Compression
Nylon
Nitrile
300
†
300
†
250
†
200
†
-40° to +200°
Polyethylene
None
125
†
125
†
125
†
125
†
-65° to +190°
Par-Barb
Barb
Nylon
None
125
†
125
†
125
†
125
†
-40° to +200°
Quick
Quick
Couplings
Disconnect
Acetal
Nitrile
120
†
120
†
120
†
N/A
-40° to +180°
Collet
TrueSeal
Push button
Ball Valves
release
Polypropylene
EPDM
150
†
N/A 150
†
150
†
0° to +255°
Collet
TrueSeal
Check
Push button
Valves
release
Acetal
EPDM
150
†
150
†
150
†
150
†
34° to +150°
Unleaded
Push button
Unleaded
Brass
release
Brass
EPDM
†
†
†
†
0° to +200°
Polyethylene
N/A
120
†
145
†
125
†
90
†
-80° to +150°
LIQUIfit
Tubing
Polypropylene
N/A
300
†
350
†
300
†
225
†
0° to +200°
†
Working pressure varies with application and temperature.
Product specifications vary with fitting configurations.
1
Product Specifications
WARNING–USER RESPONSIBILITY
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR
RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
• This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system
options for further investigation by users having technical expertise.
• The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring
that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects
of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in
any other materials provided from Parker or its subsidiaries or authorized distributors.
• To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications
provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications
and reasonably foreseeable uses of the components or systems.
1/4" 5/16" 3/8" 1/2"