Page 294 - Catalog4400.pdf

SEO Version

B-202
Hose Products Division
Parker Hannifn Corporation
Wickliffe, Ohio
88 Series Fittings
Catalog 4400 US
Use with
hoses.
88 Series Assembly Instructions
88 Series
Hose Assembly Instructions
1. Identify Over All Length (OAL) of hose assembly and the Cut
Off Allowance (COA) length of ftting(s) by use of the ftting
data table. Properly measure and mark hose. Cut hose
cleanly and squarely to length. Trim any exposed wire
reinforcement to prevent injury in service.
2. Slide clamp(s) onto hose and lubricate hose. Push hose onto
ftting until hose bottoms against stop ring or hex.
3. Position hose clamp(s) as shown and secure with a screw-
driver or wrench. Maintain “A” dimensions as shown below
for proper clamp positioning of both HC clamps and HC-H
clamps.
3A. Evenly attach double bolt clamps for maximum grip.
Note:
For permanent installation of 88 Series Fittings, an 81
Series Crimp Shell must be added. See
for assembly and crimping instructions.
IF YOU HAVE QUESTIONS CONCERNING THE PRODUCTS
OR APPLICATION OF THE PRODUCTS CONTAINED IN THIS
CATALOG, PLEASE CALL:
PARKER HOSE PRODUCTS DIVISION
TECHNICAL SERVICES DEPARTMENT
PHONE: 440-943-5700
FAX: 440-943-3129
Hose I.D.
inch
A
inch mm
-12
1/4
6.35
-16
3/8
9.53
-20
3/8
9.53
-24
1/2 12.70
-32
1/2 12.70
3A
3
2
1
A